GENERAL NOTES: <br /> 1. Wall thicknesses noted are nominal unless specifically stated otherwise. <br /> 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. <br /> 3. Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60. <br /> 4. Bend horizontal bars or provide matching hooks around all wall corners and intersections. <br /> 5. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. <br /> 6. Allowable bar placement tolerance is 1/2". Tying is not required if tolerances are met and maintained. <br /> 7. Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded <br /> into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels <br /> may be bent down for safety and covering then bent back before wall placement. <br /> 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and <br /> intersections. Walls less than 24"in length require only one anchor. Sill plates may overhang the face of the wall <br /> provided the overhang is not loaded vertically and all anchor bolt/connection tolerances are met. <br /> 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1. <br /> 10. Anchor bolts may be substituted with 1/2"diameter threaded rod epoxy grouted at same spacing with 7"embed. <br /> 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. <br /> 12. Slope grade 6"minimum downward away from foundations within first 10 feet or provide Code adequate swale. <br /> 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of <br /> adequate shoring is required when the final floor and slab systems are not in place and fully anchored. <br /> 14. Maximum inside window well dimension is 72". Well walls are to be at least 8"thick placed monolithically with <br /> house walls with horizontal bars extended into them and around corners. Provide two additional vertical bars and <br /> one additional anchor bolt each side of opening. Opening header by others. <br /> COLD WEATHER GUIDELINES: <br /> The following information is general guidelines for the placement of concrete in cold weather conditions. It is the <br /> contractor's responsibility to ensure proper means and methods are followed and that the final in place product is <br /> adequate. <br /> 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions <br /> expected. Use of extra cement,early-strength concrete,and accelerators are recommended at temperatures <br /> below 20 degrees F. <br /> 2. Concrete is to be delivered to the site in a timely manner. <br /> 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised. <br /> 4. Do not add additional water. Using water-reducing admixtures is recommended when required. <br /> 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground,snow,or ice. <br /> 6. Preheating of rebar is not required,however it is to be free of frost,snow,and ice. <br /> 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures <br /> below 10 degrees F and for the whole wall when below zero degrees F. <br /> Osweil Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 it :74 <br /> Project Name: 2017 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 <br /> Description: General Notes Phone:612-720-4639 e.:= <br /> Project# 16.100 Fax:612-886-2966 <br /> Client Name: Abfalter Brothers Concrete LLC www.oswellec.com <br /> Client Address: 15546 Cleveland Street, Elk River, MN 55330 Page S2 of S6 o <br /> 1/1/2017 <br />