<br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> Sabre Plumbing&Heating IS 1525 Long Lake Blvd.Orono;
<br /> Plymouth,MN 55447 ._, -,_ Page 4_
<br /> Total Building Summary Loads
<br /> Component Area Sen Lat Sen Total
<br /> !Description _ - Quan -___-Loss Gain GainGam;
<br /> LOW EE: Glazing-Builder Grade Low E Windows& 688 19,154 0 17,575 17,575
<br /> Sliding Door .32 U value .30 SHGC, u-value 0.32,
<br /> SHGC 0.3
<br /> 11J: Door-Metal- Fiberglass Core 41.8 2,181 0 602 602
<br /> 15A-15sffc-8:Wall-Basement, concrete block wall, R-15 1056 3,125 0 0 0
<br /> foam board to floor, no framing, no interior finish,
<br /> filled core, 8'floor depth
<br /> R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 2766.2 15,883 0 2,427 2,427
<br /> siding finish,wood studs
<br /> RJ R20 Closed Cell: Wall-Frame, Custom, Spray Foam R- 552 2,400 0 424 424
<br /> 20
<br /> R49- 16B-49: Roof/Ceiling-Under Attic with Insulation on 1228 2,457 0 1,356 1,356
<br /> Attic Floor(also use for Knee Walls and Partition
<br /> Ceilings), Custom, R49 Blown Insulation-vented
<br /> attic, asphalt shingles
<br /> 21A-20-c: Floor-Basement, Concrete slab, any thickness, 1490 3,500 0 0 0
<br /> 2 or more feet below grade, no insulation below floor,
<br /> carpet covering, shortest side of floor slab is 20'wide
<br /> 20P-30: Floor-Over open crawl space or garage, Passive, 184 560 0 52 52
<br /> R-30 blanket insulation, any cover
<br /> Subtotals for structure: 49,260 0 22,436 22,436
<br /> People: 5 1,000 1,150 2,150
<br /> Equipment: 901 4,116 5,017
<br /> Lighting: 1250 4,263 4,263
<br /> Ductwork: 1,642 134 338 472
<br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
<br /> Ventilation: Winter CFM: 180, Summer CFM: 180 6,685 4,177 999 5,175
<br /> Humidification (Winter) 16.41 gal/day: 6,019 0 0 0
<br /> AED Excursion: 0 0 3,896 3,896
<br /> Total Building Load Totals: 63,606 6,212 37,197 43,408
<br /> Check Figures __-
<br /> Total Building Supply CFM: 1,694 CFM Per Square ft.: 0.400
<br /> Square ft. of Room Area: 4,233 Square ft. Per Ton: 1,170
<br /> Volume(ft3)of Cond. Space: 35,379
<br /> Building Loads
<br /> Total Heating Required Including Ventilation Air: 63,606 Btuh 63.606 MBH
<br /> Total Sensible Gain: 37,197 Btuh 86 %
<br /> Total Latent Gain: 6,212 Btuh 14 %
<br /> Total Cooling Required Including Ventilation Air: 43,408 Btuh 3.62 Tons (Based On Sensible + Latent)
<br /> ! Notes
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> INA .rh9 Tuesday, November 07, 2017, 6:44 AM
<br /> M:\ ...\1525 Long Lake Blvd. Orono TAMOSU S