My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01341 - new structure
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1020 Mooney Lake Drive - 25-118-23-41-0012
>
Permits/Inspections
>
2017-01341 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:01 PM
Creation date
1/12/2018 2:36:52 PM
Metadata
Fields
Template:
x Address Old
House Number
1020
Street Name
Mooney Lake
Street Type
Drive
Address
1020 Mooney Lake Drive
Document Type
Permits/Inspections
PIN
2511823410012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> ZULU Mooney Lake Drive <br /> nWELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes Et bounds: out of road easement, or outer ditch. <br /> LAKE/BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE . Protected wetland . <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank Ft sewer line. (else sewer line> 12"below) <br /> Sewer line Ft baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth rep's, clean out every 100', Sch 40 pipe) <br /> FT Septic tank and risers (water tight, insulated, proper depth,existing verified by pumping) <br /> mfu 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining baffles. <br /> _ No effluent filter Et alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1300 gallons <br /> n dose pump 36 gpm 25 head VERIFY PUMP CURVE 5.5 min ON 9 hr OFF <br /> C float setting drop 7.8 inches at 25.5 gpi "DESIGNED" 4.9 inches approx float tether length <br /> 199.0 gal dose divided by gpi "INSTALLED"= inches float drop(field corrected <br /> _ LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade- 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> _ splice box / control panel /electrical connections <br /> _ flow measurement: CT, ETM, time dosed, home water meter <br /> _ mound absorption area rough up <br /> mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 24 inches. (Jar test: 2"sand leaves< 1/8"silt after 30 min) <br /> ElAbsorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> U Bermed topsoil beyond rockbed 14 upslope 13 sideslope 21 downslope <br /> cover depth of 12-18"+ VERIFY <br /> _ 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe fx fittings) <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> _ clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary Re-use existing tank certification <br /> _ monitoring plan and type <br /> well abandonment form - if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.