Laserfiche WebLink
• <br /> • Truss Repair for: Truss F10 w/ damaged Qty Ply Structural Details Provided by: <br /> 3955 Cherry Avenue plate on bottom chord 2 ' Job Refer( Becklin & Whitney <br /> Orono, MN Jruisen 7.610 s Mar IU:iPSzp7ToiCL9RMb71bK0 kyxrWY- 139 1st Ave. E. Ste 200 <br /> 0-1-8 1-2-0 P.O. Box 471 <br /> HI 2-3-7 I 0-pl H Cambridge, MN 55008 <br /> 4x7= 5x10= 3x6 FP= 3x4= <br /> 1.5x3H 3x8= 1.5x3H 3x4= 1.5x3 11 3x4= 1.5x3H 3x6 FP= 1.5x3H 3x4 11 4x5= 3x6= 1.5x3 11 3x4.= 1.5x3 <br /> 1 '2 3 4T1 5 6 7 8 9 10 12 11 12 1314 15 16 T3 17 18 19 <br /> 3�1 / \ / . /i l .. m / \. ,. 33 4 <br /> M - <br /> 31 30 29 28 27 26 25 \ 24 23 22 21 20 <br /> 3x6= 4x7= 3x10 MT16 FP= 4x8= 5x12= 4x8= 4x4= 3x8= 3x6= <br /> 1.5x3 S 3x4= <br /> Remove 2x6" scab. Glue and nail (1) 2x4"x9' SPF #2 or <br /> better (centered over damaged plate) to (1) side of the <br /> bottom chord w/ construction adhesive and 10d nails 4" <br /> O.C. A minimum of(13) nails to be installed on each side <br /> of plate w/ a min of(26) total or Simpson SDW22458 4-5/8" <br /> I screws 6" O.C.w/a min of(8) screws on each side of plate I <br /> Plate Offsets(X,Y)-- (21:0-1-8,Edge],[23:0-1-8,E w/ a min of(16) total. <br /> LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP <br /> TCLL 40.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL) -0.24 27-28 >999 480 MT20 197/144 <br /> TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(TL) -0.49 27-28 >537 240 MT16 116/127 <br /> BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.07 24 n/a n/a <br /> BCDL 5.0 Code MNSRC/TPI2002 (Matrix) Weight:139 lb FT=0%F,0%E <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 SPF No.2(flat)*Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except <br /> T2:2x4 SPF 1650F 1.5E(flat) end verticals. <br /> BOT CHORD 2x4 SPF No.2(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. <br /> WEBS 2x4 SPF Stud(flat)*Except* <br /> W2:2x4 SPF No.2(flat) Note: All rows of fasteners to be <br /> REACTIONS. (lb/size) 31=966/0-5-8 (min.0-1-8),20=133 installed into center of existing truss <br /> Max Uplift20=-208(LC 2) <br /> Max Grav31=983(LC 2),20=333(LC 3),24=2 members. End distance of fasteners <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)o to be a min of 1-3/4". Edge distance <br /> TOP CHORD 2-3=-2572/0,3-4=-2572/0,4-5=-3327/0,5-6 of fasteners to be a min of 3/4". <br /> 8-9=-2358/0,9-10=0/579,10-11=0/579,11-1 <br /> 14-15=0/2514,15-16=-388/1139,16-17=-38 hi 1N <br /> BOT CHORD 30-31=0/1535,29-30=0/3153,28-29=0/3153,27-28=0/3044,26-27=0/1208,25-26=0/1208, <br /> 24-25=-2614/0,23-24=-2540/0,22-23=-1793/0,21-22=-614/487 <br /> WEBS 2-31=-1762/0,2-30=0/1202,4-30=-673/0,6-28=0/362,6-27=-829/0,9-27=0/1367, <br /> 9-25=-1832/0,11-25=0/2358,11-24=-1515/0,18-20=-410/251,17-21=-276/528, <br /> 17-22=-608/0,15-22=0/947,15-23=-1337/0,13-23=0/698,13-24=-1160/0 <br /> NOTES- <br /> 1)Unbalanced floor live loads have been considered for this design. <br /> 2)All plates are MT20 plates unless otherwise indicated. <br /> 3)Attach ribbon block to truss with 3-10d nails applied to flat face. <br /> 4)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 208 lb uplift at joint 20. <br /> 5)Load case(s)1,2,3 has/have been modified.Building designer must review loads to verify that they are correct for the intended use of this <br /> truss. <br /> 6)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and d <br /> 7)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 I HEREBY CERTIFY THAT THIS PLAN, <br /> attached to walls at their outer ends or restrained by other means. SPECIFICATION OR REPORT WAS <br /> 8)CAUTION,Do not erect truss backwards. <br /> LOAD CASE(S)Standard PREPARED BY ME OR UNDER MY <br /> 1)Dead+Floor Live(balanced):Lumber lncrease=1.00,Plate Increase=1.00 DIRECT SUPERVISION AND THAT I AM A <br /> Uniform <br /> Vert:20-311)=-8,1-12=-100,12-19=-80 DULY REGISTERED PROFESSIONAL <br /> 2)1st Dead+Floor Live(unbalanced):Lumber lncrease=1.00,P o+''iti, ENGINEER UNDER THE LAWS OF THE <br /> Uniform Loads(plf) �` '/ <br /> Vert:20-31=-8,1-12=-100,12-19=-16 �\PM A.BEOI''; STATE OF MINNESOTA. <br /> 3)2nd Dead+Floor Live(unbalanced):Lumber Increase=1.00,f �.• %�i <br /> �' LICENSED ' <br /> I PROFESSIONAL i _ Q] 6 <br /> Continued on page 2 - ENGINEER - sf/y <br /> 18494 :Z <br /> ,09r ................ <br /> •5o WILLIAM A. BECKLIN, P.E. <br /> ��', mlIs.``, DATE: January 9, 2018 LIC. NO. 18494 <br /> ,,,or N , <br /> '',Is,Iso,` <br />