• <br /> Property address: 2120 Carriage Lane,Orono Inspector initials/Date: JS I 11/3/2017 <br /> (mm/dd/yyyy) <br /> 4. Soil Separation —Compliance component#4 of 5 <br /> Date of installation: 10/26/1999 ❑ Unknown Verification method(s): <br /> (mm/dd/yyyy) <br /> Shoreland/Wellhead protection/Foodm/ddi beverage Soil observation does not expire. Previous soil <br /> lodging? ® Yes ❑ No observations by two independent parties are sufficient, <br /> unless site conditions have been altered or local <br /> Compliance criteria: requirements differ. <br /> For systems built prior to April 1, 1996, and 0 Yes El No ® Conducted soil observation(s) (Attach boring logs) <br /> not located in Shoreland or Wellhead <br /> Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) <br /> beverage or lodging establishment: El Not applicable(Holding tank(s),no drainfield) <br /> Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) <br /> separation distance from periodically ❑ Other(See Comments/Explanation) <br /> saturated soil or bedrock. <br /> Non-performance systems built April 1, ® Yes ❑ No Comments/Explanation: <br /> 1996, or later or for non-performance <br /> systems located in Shoreland or Wellhead Boring: <br /> Protection Areas or serving a food, 1-12" 10yr 3/3 loam <br /> beverage, or lodging establishment: <br /> 13-26"10yr 414 clay loam <br /> Drainfield has a three-foot vertical <br /> separation distance from periodically No Redox <br /> saturated soil or bedrock.* <br /> " <br /> " <br /> "Ex erimental, Other" or "Performance" <br /> P ❑ Yes ❑ No Indicate depths or elevations <br /> systems built under pre-2008 Rules; Type IV ' <br /> or V systems built under 2008 Rules(7080. A. Bottom of distribution media 12"+ <br /> 2350 or 7080.2400 (Advanced Inspector <br /> License required) B. Periodically saturated soil/bedrock ! 26"+ <br /> Drainfield meets the designed vertical C. System separation 36"+ <br /> separation distance from periodically <br /> saturated soil or bedrock. <br /> D Required compliance separation' 36 <br /> Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local <br /> failing to protect groundwater. Ordinance. <br /> 5. Operating Permit and Nitrogen BMP*— Compliance component#5 of 5 ® Not applicable <br /> Is the system operated under an Operating Permit? ❑ Yes 0 No If"yes",A below is required <br /> Is the system required to employ a Nitrogen BMP? 0 Yes ❑ No If"yes", B below is required <br /> BMP=Best Management Practices)specified in the system design <br /> If the answer to both questions is "no", this section does not need to be completed. <br /> Compliance criteria <br /> a. Operating Permit number: <br /> Have the Operating Permit requirements been met? <br /> ❑ Yes 0 No <br /> b. Is the required nitrogen BMP in place and properly functioning? 0 Yes 0 No <br /> Any "no"answer indicates Noncompliance. <br /> Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded.replaced, or its use <br /> discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance.If the system is failing to protect <br /> ground water,the system must be upgraded.replaced,or its use discontinued within the time required by local ordinance.If an existing system <br /> is not failing as defined in law, and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced, or <br /> its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas. <br /> Wellhead Protection Areas, or those used in connection with food.beverage, and lodging establishments as defined in law. <br /> www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats <br /> wq-wwists4-31 • 3/16/12 Page 3 of 3 <br />