Laserfiche WebLink
Page 8 of 8 <br /> NIKING® QUICK RESPONSE <br /> TECHNICAL DATA DRY HORIZONTAL <br /> SIDEWALL SPRINKLERS <br /> • <br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 <br /> Telephone:269-945-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com <br /> 5-1m <br /> �)8' <br /> Seal the clearance space around the sprinkler barrel to avoid110 Maximum <br /> leakage of air Into the protected area and consequent formation <br /> of condensate around the sprinkler frame, which could inhibit ` <br /> operation or cause premature operation. Refer to Figure 10. • (130,230.2rrSI - <br /> If humidity and temperature „i„, � 1 NOTES To locate the <br /> differential causes condensation fill =__y 11 Deflector at deflector at the <br /> on the exposed dry sprinkler till = Maximum Distance <br /> Borrel, consider wrapping the IIII - From Vali maximum distance from <br /> PW 9 till the wall, with no <br /> exposed barrel with insulation, III! 13/16' adjustment avatable, <br /> foam insulating tape, or equivalent. IIII (20.6 mm) Ceiling order the standard <br /> IIIIdry horizontal side- <br /> Install the 1' NPT threaded Illi 4' (102 mm) Minimum wall sprinkler 1' <br /> end of the dry sidewall sprink- 6' (152 mm) Maxim/muler into the 1' NPT outlet of "I;; longer than the 'A' <br /> Sleeve finish dimension, <br /> mai <br /> a malleable iron tee fitting per 11111 \I / matches <br /> ANSI B 16.3 (Class 150) or cast _ escutcheon <br /> Iron threaded tee fitting per ?.�•i• --- k Up to 2' (50.8 mm) <br /> ANSI 16.4 (Class 125) only, frim-�_ 3-1/16' <br /> adjustment Is available. <br /> kSyII , f(77.8nm) <br /> ....,:.'N► — 5/8•J <br /> Minimum wall openings ��� i u / (15.9 mn) I 3-1/8' <br /> diameter 1-3/4'(44.5 nm) .1." <br /> L (79.4 mm) <br /> Maximum wall opening (Exposed ;;' 111 Minimum <br /> diameter' Barrel) "Il' 1-1/2'2-1/4'(57 mm). NOTES To locate the <br /> (38.1 mm) deflector at the <br /> diameter minimum distance from <br /> Exposed Barr-t" ' <br /> i• <br /> Ten mpe nture with no <br /> Ambient Temperature Surface •�- adjustmenthe t available, <br /> of Protected 40T/4'0150T/111'0160T/16tof the Watl order the standard <br /> Areae nt the Exposed 19rdR121ace Barrel 11111 <br /> Discharge End Lenpthewe Face of the wry horizontalile '- <br /> wall sprinkler 1' <br /> of the Sprinkler Tee to the Outer Deflector at shorter than the <br /> Surface of the Wnl! wry r,' Distance <br /> 'A' dimension, <br /> ,1r'.GW In.lee) In 4e1 From Wall <br /> 40'F(4'C) 0 0 0 <br /> 30'F (-I'D 0 0 0 wMey be allowed up to 18' (457 mm) for certain FM <br /> POT (-7•C) 4 (100) 0 0 Installations, Refer to the appropriate installation standards, <br /> 10'r (-12'C)'e<203) 1(25.4) 0 Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0, <br /> 0'F(-I8'C) 12(305)3(76) 0 iewThe protected area refers to the area below the ceiling, <br /> -10'F<-23'014(356)4(102)1(25.4) The ambient temperature Is the temperature at the discharge end of the sprinkler. <br /> -20T (-29'014(356)6 (152) 3 (76) For protected area temperatures that occur between the <br /> -30'F (-34'C716(406)8 (20374 <102) values listed, use the next cooler temperature. <br /> -40'F(-40'C)10(457)I (203)4 (102) wwwThe minimum required barrel length is not the same as the 'A' dimension. <br /> -50T (-46'C)20(508)10(254:6(152) Refer to Figures 3, 5, and 7 for the 'A' dimension. <br /> -60T (-5re)20(508)10(254)6 (152) Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. <br /> Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area <br /> (Adjustable Standard Dry HSW Sprinkler Is Shown) <br /> t <br /> 1 <br /> Seal Seat <br /> (or equivalent ; : j <br /> method) <br /> II' ` III�I .I . L IIS II! 1 ■I <br /> o <br /> k Clearance <br /> $ j Opening <br /> k Insulated $ Insulated <br /> $ Wall Wall <br /> Dry Sprinkler Seal on the Exterior of the Wall Dry Sprinkler Seal Within the Wall <br /> Figure 10: Dry Sprinkler Seal(Adjustable Standard Dry HSW Sprinkler is Shown) <br /> Form No. F__031993 Rev 15.1 <br />