Laserfiche WebLink
BUILDING PLANNING <br /> escape and rescue openings shall open directly into a public SECTION R311 <br /> way,or to a yard or court that opens to a public way. MEANS OF EGRESS <br /> Exception: Basements used only to house mechanical R311.1 General.Stairways,ramps,exterior egress balconies, <br /> equipment and not exceeding total floor area of 200 square hallways and doors shall comply with this section. <br /> feet(18.58 m2). R311.2 Construction. <br /> R310.1.1 Minimum opening area.All emergency escape R311.2.1 Attachment.Required exterior egress balconies, <br /> and rescue openings shall have a minimum net clear open- exterior exit stairways and similar means of egress <br /> ing of 5.7 square feet(0.530 m2). components shall be positively anchored to the primary <br /> Exception:Grade floor openings shall have a minimum structure to resist both vertical and lateral forces. Such <br /> net clear opening of 5 square feet(0.465 m2). attachment shall not be accomplished by use of toenails or <br /> nails subject to withdrawal. <br /> R310.1.2 Minimum opening height. The minimum net <br /> clear opening height shall be 24 inches(610 mm). R311.2.2 Under stair protection.Enclosed accessible space <br /> under stairs shall have walls,under stair surface and any sof- <br /> R310.1.3 Minimum opening width. The minimum net fits protected on the enclosed side with'/2-inch(13 mm)gyp- <br /> clear opening width shall be 20 inches(508 mm). sum board. <br /> R310.1.4 Operational constraints.Emergency escape and R311.3 Hallways.The minimum width of a hallway shall be <br /> I rescue openings shall be operational from the inside of the not less than 3 feet(914 mm). <br /> room without the use of keys,tools or special knowledge. <br /> R311.4 Doors. <br /> R310.2 Window wells.The minimum horizontal area of the <br /> window well shall be 9 square feet(0.9 m2),with a minimum R311.4.1 Exit door required.Not less than one exit door <br /> horizontal projection and width of 36 inches (914 mm). The conforming to this section shall be provided for each dwell <br /> area of the window well shall allow the emergency escape and ing unit. The required exit door shall provide for direct, <br /> rescue opening to be fully opened. access from the habitable portions of the dwelling to the' <br /> exterior without requiring travel through a garage.Access t . <br /> Exception:The ladder or steps required by Section R310.2.1 habitable levels not having an exit in accordance with this <br /> shall be permitted to encroach a maximum of 6 inches(152 section shall be by a ramp in accordance with Section <br /> mm)into the required dimensions of the window well. R311.6 or a stairway in accordance with Section R311.5. <br /> R310.2.1 Ladder and steps.Window wells with a vertical R311.4.2 Door type and size.The required exit door shall <br /> depth greater than 44 inches(1118 mm)shall be equipped be a side-hinged door not less than 3 feet(914 mm)in width <br /> with a permanently affixed ladder or steps usable with the and 6 feet 8 inches(2032 mm)in height.Other doors shall <br /> window in the fully open position.Ladders or steps required not be required to comply with these minimum dimensions. <br /> by this section shall not be required to comply with Sections R311.4.3 Landings at doors.There shall be a floor or land- <br /> R311.5 and R311.6. Ladders or rungs shall have an inside ing on each side of each exterior door.The floor or landing <br /> width of at least 12 inches(305 mm),shall project at least 3 at the exterior door shall not be more than 1.5 inches (38 <br /> inches(76 mm)from the wall and shall be spaced not moremmlower than the top of the threshold.The landing shall <br /> than 18 inches (457 mm) on center vertically for the full be permitted to have a slope not to exceed 0.25 unit vertical <br /> height of the window well. in 12 units horizontal(2-percent). <br /> R310.3 Bulkhead enclosures.Bulkhead enclosures shall pro- Exceptions: <br /> vide direct access to the basement.The bulkhead enclosure with <br /> the door panels in the fully open position shall provide the mini- 1. Where a stairway of two or fewer risers is located <br /> mum net clear opening required by Section R310.1.1.Bulkhead on the exterior side of a door, other than the <br /> enclosures shall also comply with Section R311.5.8.2. required exit door,a landing is not required for the <br /> exterior side of the door provided the door, other <br /> R310.4 Bars,grilles,covers and screens.Bars,grilles, cov- than an exterior storm or screen door does not <br /> ers, screens or similar devices are permitted to be placed over swing over the stairway. <br /> emergency escape and rescue openings,bulkhead enclosures, <br /> or window wells that serve such openings,provided the mini- 2. The exterior landing at an exterior doorway shall <br /> mum net clear opening size complies with Sections R310.1.1 not be more than 73/4 inches (196 mm)below the <br /> to R310.1.3,and such devices shall be releasable or removable top of the threshold,provided the door,other than <br /> from the inside without the use of a key, tool, special knowl-I <br /> an exterior storm or screen door does not swing <br /> edge or force greater than that which is required for normal over the landing. <br /> operation of the escape and rescue opening. 3. The height of floors at exterior doors other than the <br /> R310.5 Emergency escape windows under decks andI <br /> exit door required by Section 8311.4.1 shall not be <br /> porches. Emergency escape windows are allowed to be more than 73/4 inches(186 mm)lower than the top <br /> installed under decks and porches provided the location of the of the threshold. <br /> deck allows the emergency escape window to be fully opened The width of each landing shall not be less than the door <br /> and provides a path not less than 36 inches(914 mm)in height served. Every landing shall have a minimum dimension of <br /> to a yard or court. 36 inches(914 mm)measured in the direction of travel. <br /> 2006 INTERNATIONAL RESIDENTIAL CODE® 53 <br />