2016-01434 - septic
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1175 Mooney Lake Drive - 25-118-23-41-0017
>
Septic
>
2016-01434 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:10 PM
Creation date
12/8/2017 11:31:11 AM
Metadata
Fields
Template:
x Address Old
House Number
1175
Street Name
Mooney Lake
Street Type
Drive
Address
1175 Mooney Lake Drive
Document Type
Septic
PIN
2511823410017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 11/5 Mooney Lake Drive i <br /> __- WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) 6 <br /> 50'to everything 100'to dispersal area with shallow well <br /> - PROPERTY LINES setback: 10'to everything I <br /> Road setback: platted: 10'prop line. Metes& bounds: out of road easement, or outer ditch. <br /> _ LAKE/BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE . Protected Protected wetland . <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> _ <br /> WATER LINE under pressure st 10'to bed,tank&sewer line. (else sewer line> 12"below) G <br /> s <br /> r <br /> ESewer line& baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2" in 8') € <br /> (no depth reqs, clean out every 100', Sch 40 pipe) <br /> ESeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gallons none l <br /> l <br /> l <br /> _- Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. i <br /> No effluent filter&alarm f, <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> e <br /> mfg 1250 gallons i <br /> - dose pump 36 gpm 23 head VERIFY PUMP CURVE 5,7 min ON 9 hr OFF <br /> } <br /> i <br /> n float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length <br /> 205.0 gal dose divided by gpi "INSTALLED"= inches float drop (field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> _ Cam lock reachable from grade- 30" max. J-hook weep hole. Supply line access (no hard 90's) I <br /> _ 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. F <br /> _ splice box / control panel / electrical connections <br /> _ flow measurement: CT, ETM, time dosed, home water meter <br /> _ mound absorption area rough up <br /> mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 12 inches. (Jar test: 2"sand leaves < 1/8"silt after 30 min) <br /> l <br /> EAbsorption Sand beyond rock 0.0 upslope 17,0 downslope <br /> nBermed topsoil beyond rockbed 10 upslope 11 sideslope 20 downslope <br /> _ cover depth of 12-18"+ VERIFY li <br /> 3 laterals (1.2'from edge of rock) i <br /> 2.00 inch pipe size (Sch40 pipe &fittings) <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing i <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY I <br /> clean outs (no hard 90's) <br /> - 4"inspection pipe to bottom of rock, anchored VERIFY t <br /> _ Abandon existing system - if necessary Re-use existing tank certification <br /> monitoring plan and type / <br /> well abandonment form - if necessary <br /> 5 <br />