My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00758 - new structure
Orono
>
Property Files
>
Street Address
>
M
>
Mooney Lake Drive (Formeraly 300 Sixth Ave N)
>
1175 Mooney Lake Drive - 25-118-23-41-0017
>
Permits/Inspections
>
2016-00758 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:09 PM
Creation date
12/8/2017 11:18:00 AM
Metadata
Fields
Template:
x Address Old
House Number
1175
Street Name
Mooney Lake
Street Type
Drive
Address
1175 Mooney Lake Drive
Document Type
Permits/Inspections
PIN
2511823410017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Design Summary Worksheet UNIVERSITY <br /> Minnesota Pollution OF MINNESOTA . <br /> Control Agency v�N"'",- <br /> Control <br /> Owner/Client: Lot 1, Blk 2 Site A Project ID: v 06.12.13 <br /> Site Address: That part of 300 6th Ave. N.,Orono, Hennepin County Date: 4/20/15 <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 750 Gallons Per Day(GPD) Note: The estimated design flow is considered a peak flow rate <br /> including a safety factor.For long term performance, the average <br /> B. Septic Tanks: daily flow is recommended to be<60%of this value. <br /> Minimum Code Required Septic Tank Capacity: 2250 Gallons,in 2 Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in 2 Tanks or Compartments <br /> Effluent Screen: Alarm: No <br /> C. Holding Tanks Only: <br /> Minimum Code Required Capacity: Gallons,in Tanks <br /> Designer Recommended Capacity: Gallons,in Tanks <br /> Type of High Level Alarm: <br /> D. Pump Tank 1 Capacity(Code Minimum): Gallons Pump Tank 2 Capacity(Code Minimum): Gallons <br /> Pump Tank 1 Capacity(Designer Rec): Gallons Pump Tank 2 Capacity(Designer Rec): Gallons <br /> Pump 1 GPM Total Head ft Pump 2 GPM Total Head ft <br /> Supply Pipe Dia. in Dose Volume: gal Supply Pipe Dia. in Dose Volume: gal <br /> 2. SYSTEM TYPE <br /> Type of Soil Treatment and Dispersal Area* r I ype of Disuiouuon' <br /> Trench Q Bed QQ Mound I Gravity Distribution Pressure Distritx�tlon-Level 0 Pressure Distrixition-Unlevel <br /> o Drip Q Holding Tank 0 At-Grade *Selection Required Benchmark Elevation: sea level ft <br /> Benchmark Location: topography map <br /> System Type Type of Distribution Media: <br /> 111 <br /> Type I n Type II ❑Type III E Type IV ❑Type V <br /> Drainfield Rock Registered Treatment Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 26 in 2.2 ft B. Measured Land Slope%: 6.0 % <br /> C. Elevation of Limiting Layer: D. Soil Texture: Clay Loam <br /> E. Loc.of Restricive Elevation: F. Soil Hyd. Loading Rate: 0.45 GPD/ft2 <br /> G. Minimum Required Separation: 36 in 3.0 ft H. Perc Rate: MPI <br /> I. Code Maximum Depth of System: Mound in Comments: <br /> 4. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Area ft2 Sidewall Depth in Trench Width in <br /> Total Lineal Feet ft Number of Trenches Code Maximum Trench Depth in <br /> Contour Loading Rate ft Designer's Max Trench Depth in <br /> Bed Design Summary <br /> Absorption Area ft2 Media Below Pipe in Code Maximum Bed Depth in <br /> Bed Width ft Bed Length ft Designer's Max Bed Depth in <br />
The URL can be used to link to this page
Your browser does not support the video tag.