Laserfiche WebLink
t c ` t I GENERAL INFORMATION: <br /> i '' ' �A�} � SPRAYTITE 158 is a spray polyurethane foam(SPF)system intended for installation by qualified contractors trained in <br /> 4 u ;,, the processing and application of SPF systems,as well as the plural-component polyurethane dispensing equipment <br /> #7 �- F } �{ &'`F`' required to do so. Contractors and applicators must comply with all applicable and appropriate storage,handling, <br /> +:" i x �t. processing and safety guidelines. BASF Polyurethane Foam Enterprises LLC technical service personnel should be <br /> r <br /> �, r -.•,-,.•:,.--,,.-. :-:,..;..!.•:,., .:,...-„,,,,,,,..,,,,„ <br /> consulted in all cases where application conditions are questionable. <br /> t � : 4 CAUTIONS AND RECOMMENDATIONS: <br /> :' s : `, SPRAYTITE 158 is designed for an application rate of t/2 inch minimum to 2 inches maximum per pass. Once installed <br /> �s ti(t „' material has cooled it is possible to add additional applications in order to increase the overall installed thickness of SPF. <br /> yi,r ;�1.-' t,;t:, ' This application procedure is in compliance with the Spray Polyurethane Foam Alliance(SPFA). <br /> e't.,.y,.`k �¢ ., , t -:',c-q:,..;:'.,,:;-.11, SPRAYTITE 158 is NOT designed for use as an EXTERIOR roofing system. BASF Polyurethane Foam Enterprises <br /> r� `,Z . ;, LLC offers a separate line of products for exterior roofing applications. For more information please contact your sales <br /> representative. <br /> �,%},,z' ." „" .„: � 4 <br /> Cold-storage structures such as coolers and freezers demand special design considerations with regard to thermal <br /> p . , , 4� i insulation and moisture-vapor drive. SPRAYTITE 158 should NOT be installed in these types of constructions unless <br /> �; y Wt ^a ttrw the structure was designed by a design professional for specific use as cold storage. <br /> �V�et,z����n"�'nit °� '� ra+'r �,� �. <br /> 'a � ' , s:'.: ,r;,h SPRAYTITE 158 is designed for installation in most standard construction configurations using common materials such <br /> {�' �� t�a' as wood and wood products,metal and concrete. SPRAYTITE 158 has performed successfully when sprayed onto <br /> �,7` . fig,, * wood substrates down to 40°F. For other substrates,please consult your BASF Polyurethane Foam Enterprises LLC <br /> .. v° � sales or technical service representative for specific recommendations. <br /> ? � fEt Foamplastic materials installed in walls or ceilings may�''.1."';'''',..,_• , �, �� �,'�".�� ,�, g present a fire hazard unless protected by an approved,fire- <br /> 41......1-;..•.'1 <br /> ire- <br /> r , 7 it , w , ; <br /> �'� � F: �, resistant thermal barrier with a finish rating of not less than 15 minutes as required by building codes. Rim joists/header <br /> -0, '-'::::*?.'Z''''-':!•,°''''' areas, in accordance with the IRC and IBC may not require additional protection. Foam plastic must also be protected <br /> „: ' '' against ignition by code-approved materials in attics and crawl spaces. See relevant Building Codes and <br /> �,,� � www.iccsafe.orq for more information. <br /> t The SPRAYTITE 158 foam systems are NOT recommended for medical uses;such as,splints or casts for broken bones <br /> yp <br /> nor other medical or pharmaceutical uses.h, <br /> i t•:•;:::::-.1',''' :' In addition to reading and understanding the MSDS,all contractors and applicators must use appropriate respiratory, <br /> skin and eye Personal Protective Equipment(PPE)when handling and processing polyurethane chemical systems. <br /> ` • x Personnel should review the following document published by Spray Polyurethane Foam Alliance(SPFA): <br /> ' " AX-171 Course 101-R Chapter 1: Health, Safety and Environmental Aspects of Spray Polyurethane Foam and <br /> Coverings <br /> ``.`- , and the following document available from the Center for the Polyurethanes Industries(CPI): <br /> Model Respiratory Protection Program for Compliance with the Occupational Safety and Health Administration's <br /> Respiratory Protection Program Standard 29 C.F.R.§1910.134 <br /> t <br /> ';',.i,.0:::”. As with all SPF systems improper application techniques should be avoided.Examples of improper application <br /> : techniques include,but are not limited to excessive thickness of SPF,off-ratio material and spraying into or under rising <br /> SPF.Potential results of improperly installed SPF include: dangerously high reaction temperatures that may result in fire <br /> Via, .°"' - - and offensive odors that may or may not dissipate. Improperly installed SPF must be removed and replaced with <br /> t ' i ` properly installed materials. <br /> 5,4.1-, 1.. , r .-4 LARGE MASSES of SPF should be removed to an outside safe area,cut into smaller pieces and allowed to cool before <br /> ,., K . fr ''discarding into any trash receptacle. <br /> 6 ••:''.;:f,;„.''--..:'.:.L#` , a. SPF insulation is combustible. High-intensity heat sources such as welding or cutting torches must not be used in <br /> x r ,at q: contact with or in close proximity to SPRAYTITE 158 or any polyurethane foam. <br /> t.+;. e's '-.� ,tt <br /> vt <br /> kZ3-75::,r:'''''1.64;''::(.1114, SHELF LIFE AND STORAGE CONDITIONS: <br /> r„ i,� k: SPRAYTITE 158 Series has a shelf life of approximately three months from the date of manufacture when stored in <br /> ` . '" ;` original,unopened containers at 50-80°F. As with all industrial chemicals this material should be stored in a covered, <br /> ,� . 3 t �,.^�.,�.. secure location and never in direct sunlight. Storage temperatures above the recommended range will shorten shelf life. <br /> t , f Storage temperatures above the recommended range may also result in elevated headspace pressure within packages. <br /> F 1i <br /> I; r,' s r . LIMITED WARRANTY INFORMATION—PLEASE READ CAREFULLY: <br /> A xMy <br /> di <br /> 2' n, h'''.44'I. • f The information herein is to assist customers in determining whether our products are suitable for their applications. Our <br /> is' products are only intended for sale to industrial and commercial customers. Customer assumes full responsibility for <br /> (' -_ quality control,testing and determination of suitability of products for its intended application or use. We warrant that our <br /> p� 1d " products will meet our written liquid component specifications. We make no other warranty of any kind,either express or <br /> +pn'1 " implied,by fact or law,including any warranty of merchantability or fitness for a particular purpose. Our total liability and <br /> t ;r1 ' ' customers'exclusive remedy for all proven claims is replacement of nonconforming product and in no event shall we be <br /> t: - �«, ,2 � 4\, liable for any other damages. <br /> 7.V •" `r V?1, 4 �' . RECEIVED fir" s <br /> '' L � 4 f Seal and Insulate <br /> +�< l` -1'""f with ENERGY STAR JUN` `�dP. <br /> x ' <br /> '�. Insulation saves energywhen installed <br /> r .t,' LEARN MORE AT <br /> 4 1'yA -�"�` F; _� energystargov according to ENERGY STAR guidelines. CITY OF ORONO <br />