My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-P10863 - new structure
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3605 North Shore Drive - 08-117-23-34-0011
>
Permits/Inspections
>
2007-P10863 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:46:02 PM
Creation date
11/29/2017 1:00:15 PM
Metadata
Fields
Template:
x Address Old
House Number
3605
Street Name
North Shore
Street Type
Drive
Address
3605 North Shore Dr
Document Type
Permits/Inspections
PIN
0811723340011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STRUCTURAL NOTES <br /> MATERIAL STRENGTHS <br /> Reinforcing Steel Fy= 60,000 p.s.i. (A615 grade 60) <br /> Concrete F'c= Compressive strength in 28 days <br /> 3,000 p.s.i. for footings <br /> 3,000 p.s.i. for masonry grout <br /> 3,500 p.s.i. for interior slabs on grade <br /> 4,000 p.s.i. unless noted <br /> Masonry fm= 1,750 p.s.i. unless noted <br /> DESIGN LIVE LOADS <br /> Roofs 50 p.s.f. ground snow load <br /> Typical Floors 40 p.s.f. <br /> Garage Slab 50 p.s.f. <br /> Basic Wind Speed 90 m.p.h. (3 second gust) <br /> DESIGN CODES-LATEST EDITIONS <br /> International Building Code <br /> Minnesota State Building Code <br /> American Concrete Institute <br /> CRSI Manual of Standard Practice <br /> National Design Specifications for Stress-Graded Lumber and its Fastenings <br /> National Concrete Masonry Association <br /> COORDINATION-ARCHITECTURAL, MECHANICAL AND ELECTRICAL ITEMS <br /> Location, dimensions and details of recesses, depressions, openings and equipment supports <br /> shall be verified by reference to architectural, mechanical and electrical drawings. <br /> EXISTING CONDITIONS <br /> Verify all dimensions, elevations, and details of existing structures where they affect this <br /> construction. Notify engineer if there are any deviations from the contract documents. Field <br /> verify dimensions and elevations prior to fabrication of structural members. <br /> TEMPORARY BRACING <br /> Provide temporary lateral support for all walls until walls are adequately braced by floor or roof <br /> structure. Provide required temporary bracing for structural steel until permanent bracing and <br /> walls are in place. <br /> OPENINGS <br /> Verify size and location of all openings with architectural and mechanical drawings. Openings in <br /> floor and roof not shown on structural drawings must be placed between structural members. <br /> The contractor shall provide sleeves through concrete slabs,joists and beams for all plumbing. <br /> Spread reinforcing as required to provide concrete cover for reinforcing. <br />