Laserfiche WebLink
10 or more Sewage tanks shall be sized as other establishments per Minnesota Rules <br />chapter 7080. <br />c. Pumping stations. In order to standardize installation and electrical connection methods, <br />the following pumping station requirements must be met in addition to Minnesota Rules <br />chapter 7080: <br />1. Electrical connection. <br />A watertight, lockable electrical box must be mounted on a four -inch -by -four -inch <br />treated redwood or cedar post. <br />ii. All electrical connections shall be made within the box. Pump connection must <br />not be made using a direct line (plug-in only). Wire entry to the electrical box shall <br />be sealed with a watertight material such as foam or putty. <br />iii. Alarm and pump floats shall be on separate electrical circuits. <br />iv. Electrical wire from the power supply must not run over any tanks but must be <br />laid beside the tanks and placed in conduit along the electrical post. <br />v. Electrical cords from the pump and floats must be run through a two-inch PVC (or <br />equivalent) conduit (schedule 80) with a one -inch gap between the conduit and <br />the electrical box. Electrical cords must not run through or under the manhole <br />cover. Wires must not have ground contact. <br />2. Pumping chamber. <br />Pressure pipe exiting the pumping chamber must be laid on a uniform slope up <br />to the soil treatment area for proper drain back. The pressure pipe must be <br />sleeved inside a larger diameter pipe for additional support if spanning ground <br />that has been excavated. If the pipe at the tank must be lower than union to get <br />elevation for drain back, a one -quarter -inch weep hole must be used. <br />ii. When the soil depth above the pressure distribution pipe is less than 3% feet, <br />insulation must be added to achieve an insulating factor equal to 3% feet of soil <br />to decrease the potential for freezing (Styrofoam or concentric piping are <br />acceptable methods). Piping under hardcover, such as tennis courts or driveways, <br />shall be insulated pipe or equivalent. <br />iii. A reserve capacity equaling 75 percent of the anticipated daily flow must be <br />allowed in the pumping chamber between the alarm activation level and the <br />pump tank inlet. <br />d. Drainfields. <br />1. Trenches. Trenches must meet Minnesota Rules chapter 7080. <br />2. Mounds and at -grades. Mounds and at -grades must meet specifications per <br />Minnesota Rules chapter 7080. <br />(3) Compliance standards. <br />a. A new system shall be located, designed and constructed as a code system. <br />Page 3 <br />