My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10446 - retaining wall
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3587 North Shore Drive - 08-117-23-34-0056
>
Permits/Inspections
>
2006-P10446 - retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:46:32 PM
Creation date
11/28/2017 1:54:14 PM
Metadata
Fields
Template:
x Address Old
House Number
3587
Street Name
North Shore
Street Type
Drive
Address
3587 North Shore Dr
Document Type
Permits/Inspections
PIN
0811723340056
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> roughly the same for the replacement wall, do not appear to have caused any bearing <br /> capacity problems to date. <br /> Recornmendations <br /> It is recommended that the existing retaining walls be replaced so as to minimize any <br /> further impact on the driveway and possibly on the house. Replacement walls can be built <br /> at the site.because the reason for the wall movement is the deterioration of the timbers <br /> and the connections between them and not because the site as a whole appears to exhibit <br /> any detrimental factors that would preclude a retaining wall from performing <br /> satisfactorily. <br /> We have analyzed the boulder wall option prepared by the contractor Mr. Sundby <br /> proposes to perform the wall replacement work. Our computations of the boulder wall <br /> depicted in his drawings reveal that the wall will be stable provided: <br /> • adequate drainage is incorporated into the design by way of free-draining backfill <br /> • backfill material is adequately compacted <br /> • sufficient quantities of geosynthetics are used to reinforce the backfill soil <br /> (preferably using a wrap-around facing) <br /> � the design height and setback of the walls (tiers) is not exceeded. <br /> Thank you for this opportunity to provide assistance on your project. If you have any <br /> questions, please call Jedediah Greenwood at (952) 832-2773 or Steve Klein at <br /> (952) 832-2809. <br /> Enclosures <br /> I hereby certify that this Report was prepared by me or under by direct <br /> supervision and that I am a duly Licensed Professional Engineer under the <br /> aws o e StatP of Minnes�ta. <br /> , <br /> � � <br /> en M. Klein <br /> Date: „��, Reg. No. 12759 <br />