Laserfiche WebLink
i � <br /> � <br /> I <br /> � �O� <br />� O O <br />; � ? <br /> � � _` F <br />` �'�9A�H�g�'G~ Fire Inspection Report <br />� . � <br /> Property Name �- �-�= s,^� G �� �',µ_�. Date_'��z� q � <br /> Property Address 3,�E 2 �/ R!o w f�I�.. S4 0.•a �3�,OCc. Class. ��-.3' <br /> Owner Name �i�1 j�R....w, r.s.. ^ Phone# ''�7/ - 9 L O� <br />� Contact Person ��e„�e�. �C'c, s'f o��v+ Phon Fa/2 � 7 Z•`f/x G <br />� Const. Type Const. Year r q6� Addit. Year <br /> i <br /> I <br /> I <br />� <br /> N Y NA 1.Exteriar N Y NA N Y NA �,SnHnkier Systems <br /> ❑ � ❑a.Fre Lanes marked/unobstructed ❑ � ❑e.Storage maintained 2'beiow ceiling ❑ ❑ �a.Adequate coverage <br /> l�l ❑ ❑b.Address�sibie (unsprinklered) ❑ ❑ [�b.Controls readily accessible <br /> ❑ ❑ �c.Fire hydrant(s)accessibie ❑ ❑ �f. Storage maintained 18"below ❑ ❑ �c.Valves lodced open or supervised <br />� ,� ❑ ❑d.Combustible aawmulation acceptable sprinkler heads ❑ ❑ �d.Properly serviced <br /> I (� ❑ ❑e.Gas Meter/piping protected � ❑ ❑g.Aisles maintained-44'min. ❑ ❑ �e.Heads in good condition <br /> ❑ ❑ (�f. F.D.connections visible/good ❑ � ❑h. Rubbish,oily rags,waste material ❑ ❑ (�f. Wrench/spare heads present <br /> iconditions properly stored <br /> 10.Fire Alarm Equf inent <br /> 2.Exit Features 5.FlammablelComb.Linyids ❑ ❑ I�a.Detectors(smoke,heat)properly <br /> ❑ �' ❑a.Adequate number of exits ❑ � ❑a.Proper quantities installed <br /> ❑ � ❑b.Exits,aisles and corridors free of ❑ � ❑b.Proper storage/dispensing ❑ ❑ b.Pull stations properly instalied <br /> obstructions ❑ � ❑c.No sources of igni6on ❑ ❑ .Detectors needed <br /> ❑ � ❑c.Exits openable from inside ❑ I� ❑d.Adequate ventilation ❑ ❑ d.Properly serviced/maintained <br /> ❑ � ❑d.Exit hardware present and operational C7 � ❑e.Proper electrical equipment ❑ ❑ [�e.Tests/drills conducted <br /> � ❑ ❑e.Exit signs present <br /> ❑ ❑ ❑f. Exit corridors protected 6. tility.Mechanical.HVAG Eaui� 11.Other Fire Protectlon Ea�� <br /> ❑ � ❑g.Emergency IighGng present and ❑ Q ❑a. Relief valve present on boilers and ❑ ❑ a.Standpipes needed <br /> operational water heaters ❑ ❑ .Standpipemose in good condition <br /> ❑ ❑ �h.Occupant load posted and maintained ❑ � ❑b.Shut off valve present on gas ❑ ❑ c.Adequate coverage <br /> ❑ � ❑i, interior finish acceptable appliances ❑ ❑ ($d.Hood system-fuel shutoff present <br /> ❑ � ❑c.Adequate clearances between ❑ ❑ �e. Properly serviced/maintained <br /> 3.Constructlon Features combustibles and appliances <br /> ❑ �; ❑a.Fre separa6ons present and ❑ � ❑d.Clean ducts and filters 12.Electrical <br /> maintained ❑ � ❑a.Appliances/fixtures in good condition <br /> ❑ ��b.Structural elements intact 7.Flre Extingulshers ❑ ❑ I�b.Overcurrent protecGon present <br /> ❑ � ❑c.Rated fire doors present and ❑ � ❑a.Readily accessible/suitable loca6on ❑ � ❑c.Proper use of wiring,connections, <br /> operational(dosing/latching) ❑ [� ❑b.Proper number and type equipment <br /> ❑ � ❑d.Vertical openings acceptable ❑ � ❑c. Properly serviced/maintained ❑ (�- ❑d. Extension cords not used in place of <br /> • fixed wiring <br /> �� I,r�❑ ❑e.30'dear access to panels provided <br /> � ❑ ❑a.Storage neat and orderly ❑ ❑ . Proper quantities <br /> ❑ ($ ❑b.No combustible storage in boiler or ❑ ❑ .Proper Storage/Dispensing 13,�er• � <br /> mechanical rooms ❑ ❑ [�c.Proper Separa6on/Compatabiliry ❑ ❑ ❑ �./E c�. �e�r�e!`" <br /> ❑ (8. ❑c.No combustible storage in unprotected ❑ ❑ �d.Marking/ldentification present ❑ ❑ ❑ " <br /> a�a ❑ ❑ �e.Compressed gas cylinders secured ❑ ❑ ❑ <br /> ❑ [� ❑d.No combustible storage under ❑ ❑ ❑ <br /> unprotected stainNays <br /> Persans an Inspection: <br /> FOR FURTFiER ASSISTANCE, PLEASc CONTACT INSPECTOR NAMED BELOW. <br /> Owner/Rep.: `�\,' Inspector: �� ����� �7�^ ���� <br /> J iSianan�rs� iSmnaiure� ipna�a� <br /> i . <br />