My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
fire inspection report
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3324 North Shore Drive - 08-117-23-41-0012/21 and 44/0005
>
Misc
>
fire inspection report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:47:07 PM
Creation date
11/15/2017 10:32:39 AM
Metadata
Fields
Template:
x Address Old
House Number
3324
Street Name
North Shore
Street Type
Drive
Address
3324 North Shore Dr
Document Type
Misc
PIN
0811723410021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i � <br /> � <br /> I <br /> � �O� <br />� O O <br />; � ? <br /> � � _` F <br />` �'�9A�H�g�'G~ Fire Inspection Report <br />� . � <br /> Property Name �- �-�= s,^� G �� �',µ_�. Date_'��z� q � <br /> Property Address 3,�E 2 �/ R!o w f�I�.. S4 0.•a �3�,OCc. Class. ��-.3' <br /> Owner Name �i�1 j�R....w, r.s.. ^ Phone# ''�7/ - 9 L O� <br />� Contact Person ��e„�e�. �C'c, s'f o��v+ Phon Fa/2 � 7 Z•`f/x G <br />� Const. Type Const. Year r q6� Addit. Year <br /> i <br /> I <br /> I <br />� <br /> N Y NA 1.Exteriar N Y NA N Y NA �,SnHnkier Systems <br /> ❑ � ❑a.Fre Lanes marked/unobstructed ❑ � ❑e.Storage maintained 2'beiow ceiling ❑ ❑ �a.Adequate coverage <br /> l�l ❑ ❑b.Address�sibie (unsprinklered) ❑ ❑ [�b.Controls readily accessible <br /> ❑ ❑ �c.Fire hydrant(s)accessibie ❑ ❑ �f. Storage maintained 18"below ❑ ❑ �c.Valves lodced open or supervised <br />� ,� ❑ ❑d.Combustible aawmulation acceptable sprinkler heads ❑ ❑ �d.Properly serviced <br /> I (� ❑ ❑e.Gas Meter/piping protected � ❑ ❑g.Aisles maintained-44'min. ❑ ❑ �e.Heads in good condition <br /> ❑ ❑ (�f. F.D.connections visible/good ❑ � ❑h. Rubbish,oily rags,waste material ❑ ❑ (�f. Wrench/spare heads present <br /> iconditions properly stored <br /> 10.Fire Alarm Equf inent <br /> 2.Exit Features 5.FlammablelComb.Linyids ❑ ❑ I�a.Detectors(smoke,heat)properly <br /> ❑ �' ❑a.Adequate number of exits ❑ � ❑a.Proper quantities installed <br /> ❑ � ❑b.Exits,aisles and corridors free of ❑ � ❑b.Proper storage/dispensing ❑ ❑ b.Pull stations properly instalied <br /> obstructions ❑ � ❑c.No sources of igni6on ❑ ❑ .Detectors needed <br /> ❑ � ❑c.Exits openable from inside ❑ I� ❑d.Adequate ventilation ❑ ❑ d.Properly serviced/maintained <br /> ❑ � ❑d.Exit hardware present and operational C7 � ❑e.Proper electrical equipment ❑ ❑ [�e.Tests/drills conducted <br /> � ❑ ❑e.Exit signs present <br /> ❑ ❑ ❑f. Exit corridors protected 6. tility.Mechanical.HVAG Eaui� 11.Other Fire Protectlon Ea�� <br /> ❑ � ❑g.Emergency IighGng present and ❑ Q ❑a. Relief valve present on boilers and ❑ ❑ a.Standpipes needed <br /> operational water heaters ❑ ❑ .Standpipemose in good condition <br /> ❑ ❑ �h.Occupant load posted and maintained ❑ � ❑b.Shut off valve present on gas ❑ ❑ c.Adequate coverage <br /> ❑ � ❑i, interior finish acceptable appliances ❑ ❑ ($d.Hood system-fuel shutoff present <br /> ❑ � ❑c.Adequate clearances between ❑ ❑ �e. Properly serviced/maintained <br /> 3.Constructlon Features combustibles and appliances <br /> ❑ �; ❑a.Fre separa6ons present and ❑ � ❑d.Clean ducts and filters 12.Electrical <br /> maintained ❑ � ❑a.Appliances/fixtures in good condition <br /> ❑ ��b.Structural elements intact 7.Flre Extingulshers ❑ ❑ I�b.Overcurrent protecGon present <br /> ❑ � ❑c.Rated fire doors present and ❑ � ❑a.Readily accessible/suitable loca6on ❑ � ❑c.Proper use of wiring,connections, <br /> operational(dosing/latching) ❑ [� ❑b.Proper number and type equipment <br /> ❑ � ❑d.Vertical openings acceptable ❑ � ❑c. Properly serviced/maintained ❑ (�- ❑d. Extension cords not used in place of <br /> • fixed wiring <br /> �� I,r�❑ ❑e.30'dear access to panels provided <br /> � ❑ ❑a.Storage neat and orderly ❑ ❑ . Proper quantities <br /> ❑ ($ ❑b.No combustible storage in boiler or ❑ ❑ .Proper Storage/Dispensing 13,�er• � <br /> mechanical rooms ❑ ❑ [�c.Proper Separa6on/Compatabiliry ❑ ❑ ❑ �./E c�. �e�r�e!`" <br /> ❑ (8. ❑c.No combustible storage in unprotected ❑ ❑ �d.Marking/ldentification present ❑ ❑ ❑ " <br /> a�a ❑ ❑ �e.Compressed gas cylinders secured ❑ ❑ ❑ <br /> ❑ [� ❑d.No combustible storage under ❑ ❑ ❑ <br /> unprotected stainNays <br /> Persans an Inspection: <br /> FOR FURTFiER ASSISTANCE, PLEASc CONTACT INSPECTOR NAMED BELOW. <br /> Owner/Rep.: `�\,' Inspector: �� ����� �7�^ ���� <br /> J iSianan�rs� iSmnaiure� ipna�a� <br /> i . <br />
The URL can be used to link to this page
Your browser does not support the video tag.