My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011610 - mechanical
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3290/3292 North Shore Drive - 08-117-23-44-0020
>
Permits/Inspections
>
1999-011610 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:17:50 PM
Creation date
11/15/2017 9:46:12 AM
Metadata
Fields
Template:
x Address Old
Address
3290/3292 North Shore Dr
Document Type
Permits/Inspections
PIN
0811723440020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4• <br /> < � <br /> Y <br /> .� <br /> Component Area Sen. Lat. Sen. Total <br /> Description �uan Loss Gain Gain Gain <br /> 4A Window Double Pane &Storm Clear Glass Wood Frame 40 i,254 0 1,000 1,000 <br /> 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 452 2,287 0 587 587 <br /> 161 Ceiling R-44 Insulation 386 817 0 391 391 <br /> 201 Floor Over Open Crawl Carpet+ R-19 386 1,705 0 278 278 <br /> Subtotals for structure: 1,264 6,063 0 2,256 2,256 <br /> Active People: 0 0 0 0 0 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 0 0 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 0 <br /> Infiltration: Winter CFM: 15.4, Summer CFM: 10.3 40 1,563 252 22fi 476 <br /> Ven�lation: Winter CFM: 0.0, Summer CFM: OA 0 0 0 0 0 <br /> Sensible Gain Total: 2,482 <br /> Temperature Swinq Multiplier: X1.00 <br /> _System Load Totals: 7,626 252 2,482 2,734 <br /> F <br /> Supply CFM: 113 CFM per square foot: 0.292 <br /> Square feet of�oom area: 386 Square feet per ton: 1,399.678 <br /> Total heating required with outside air: 7,626 Btuh 7.626 MBH <br /> Total sensibie gain: 2,482 Btuh 91 % <br /> Total latent gain: 252 Btuh 9 % <br /> Total cooling required with outside air: 2,734 Btuh 0.228 Tons (based on sensible + latent) <br /> 0.276 Tons (based on 75%sensible capacity) <br /> S <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Tuesday,April 06,1999 <br />
The URL can be used to link to this page
Your browser does not support the video tag.