<br /> = FtHVAC Residentiat HVAC l.oad Calculations Elite Software Developmen4,inc.
<br /> ��Auer Steel&Heating 5uppfy Co AIR-IT JONES RESIDENCE
<br /> ; �riAstwaukee Wt 5'�2U9-�224- -- . _ Page 4� '
<br /> - --_ _-- -
<br /> --- - -
<br /> Tota/ Building Summa�Loads
<br /> _-- --
<br /> � _ __ -- --- - ----
<br /> f Component '' Area ' Sen Lat - _ Sen Total ;,
<br /> i � _ Descri�tion -- --- ___: � Quan ._ ..Loss_ Gain a ...G�in� �ain �
<br /> 3A Window Double Pane Clear Glass�VVood�Frame� ���� 460 20
<br /> _ . _. „ .. ... _�W.
<br /> ,783 0 14,299 14,299
<br /> 8M Glass Door pouble Clear Glass Wood Frame 63 2,847 0 4,410 4,410
<br /> 10D Door Wood Solid Core 21 792 0 180 180 '
<br /> 11C Door Metal Polystyrene Core 21 809 0 184 184
<br /> 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 2,981 14,666 0 3,327 3,327
<br /> ! 15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,493 6,245 0 0 0
<br /> 161 Ceiling Under Vent. Attic- R-44 Insulation 2,076 3,915 0 1,862 1,862
<br /> 19J Floor Over Basement/Encl Crawl Carpet+ R-30 426 611 0 0 0
<br /> � 21A Basemt Floor 2'or More Below Grade 1,430 2,814 0 0 0
<br /> � ----- -- -- ---- - _ _ _...�.. . _ _
<br /> Subtotals for structure: 53,482 0 24,262 24,262
<br /> People: 0 0 0 0
<br /> ' Equipment: 0 0 0
<br /> Lighting: q 0 0
<br /> Ductwork: 0 0 0 0
<br /> : Infiltration: Winter CFM: 496, Summer CFM: 283 43,385 5,965 4,536 10,501
<br /> Ventilation: Winter CFM: 0, Summer CFM: 212 0 4,474 3,401 7,876
<br /> �: Sensible Gain Total: 32,199
<br /> � Tem�erature Swing Multiplier: __ X 1.00
<br /> , __. _ _ .._...._ _ _
<br /> E Total Building Load Totals: 96,867 10,439 32,199 42,639
<br /> �
<br /> �
<br /> __ .._.. _.... _.. .
<br /> _, ,. , __
<br /> __.. .TT
<br /> Check Fi�ures --- -- --. _
<br /> -. .. ._.,�. .... .. . _ _ . ...
<br /> � Total Building Supply CFM: 1,537 CFM Per Square Foot: 0.301
<br /> Square Feet of Room Area: 5,111 Square Feet Per 7on: 1,438.417 '
<br /> ------ __ .. ...� _._..� .,.
<br /> '�� �Building Loads _ m_ _.�__. . _ �__ __ . _ w.. . _....
<br /> Total Heating Required With Outside Air: J6,867 Btuh 96.867 MBH
<br /> Total Sensible Gain: 32,1�9 6tuh 76 %
<br /> Total Latent Gain: 1 a,�139 Stuh 24 °/a
<br /> Total Cooling Required With Outside Air: 42,639 Btuh 3.553 Tons (Based On Sensible+ Latent)
<br /> 4.165 Tons (Based On 77% Sensible Capacity)
<br /> - -- �- - - -- . . _ . __ . _. .
<br /> ( �Notes __
<br /> -- -__. -. _,_ ___ �.__...__. --- - ------- ---. .._.._ ...
<br /> � Calculations are based on 7th edition of ACCA Manual J. T . M ��
<br /> � All computed results are estimates as building use and weather may vary.
<br /> 1 Be sure to select a unit that meets both sensible and latent loads.
<br /> I
<br /> C:\Elite\Rhvacw\Projects�AlR IT JONES.rhv Tuesday, September 29, 2009, 5:21 PM