My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Renovate/addition project manual-1997
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2625 North Shore Drive - 09-117-23-42-0003
>
Misc
>
Renovate/addition project manual-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:23 PM
Creation date
10/19/2017 12:55:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2625
Street Name
North Shore
Street Type
Drive
Address
2625 North Shore Dr
Document Type
Misc
PIN
0911723420003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> WOODHOUSE RESIDENCE <br /> 2 . 02 BASIC MATERIALS <br /> � <br /> A. Steel channel: Galvanized or painted steel . � <br /> B. Miscellaneous Hardware: Treat for corrosion resistance. <br /> PART 3 EXECUTION � <br /> 3 . 01 EXISTING ELECTRICAL WORK. � <br /> A. Verify that abandoned wiring and equipment serve only <br /> abandoned facilities . <br /> B. Disconnect existing electrical systems in walls, floors, � <br /> and ceilings indicated for removal . <br /> � <br /> � `C. Coordinate utility service outages and recorinections with � <br /> Utility Company and Owner. <br /> D. Provide temporary wiring and connections to maintain � <br /> existing systems in service during construction. <br /> 1 . Existing Electrical Service: Maintain existing system <br /> in service until new service is complete [and existing � <br /> loads are reconnected] . <br /> 2 . Existing Electrical Feeders and Branch Circuits: <br /> Maintain feeders and branch circuits in service until � <br /> replacement circuits are installed and ready to <br /> connect. <br /> 3 . Existing Security Alarm System: Maintain existing <br /> system in service until adjusted system is accepted. � <br /> 4 . Existing Telephone System: Maintain existing system in <br /> service until completion of Work. <br /> E. Remove, relocate, and repair existing installations to � <br /> accommodate new construction. <br /> 1 . Remove abandoned wiring to source of supply. <br /> 2 . Remove exposed abandoned conduit and boxes, [including <br /> abandoned conduit above accessible ceiling finishes . ] � <br /> 3 . Disconnect abandoned outlets and remove devices . <br /> 4 . Provide blank cover for abandoned outlets which are not <br /> removed. � <br /> 5 . Disconnect and remove abandoned panelboards and <br /> distribution equipment. <br /> 6 . Disconnect and remove electrical devices and equipment � <br /> serving utilization equipment that has been removed. <br /> 7 . Disconnect and remove abandoned luminaires, brackets, <br /> stems, hangers, and other accessories . � <br /> 8 . Disconnect and remove items as indicated on drawings . <br /> F. Repair adjacent construction and finishes damaged during <br /> removal of existing electrical work. � <br /> :±-� G. Maintain access to existing, active electrical <br /> �, installations . <br /> � <br /> BASIC ELECTRICAL - 16050-2 � <br />