My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Renovate/addition project manual-1997
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2625 North Shore Drive - 09-117-23-42-0003
>
Misc
>
Renovate/addition project manual-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:23 PM
Creation date
10/19/2017 12:55:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2625
Street Name
North Shore
Street Type
Drive
Address
2625 North Shore Dr
Document Type
Misc
PIN
0911723420003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 16112 � <br /> NM&NMC CABLE <br /> ' <br /> 1.00 GENERAL <br /> A. NM & NMC Cable may be used in lieu of conduit and wire where allowed by the � <br /> National Electric Code(NEC)and/or approved by the local electrical inspector. <br /> B. Conductors shall be a minimum of #14 AWG with a maximum of #2 AWG. All , <br /> conductors shall be 98% copper, with one bare conductor for grounding purposes <br /> only. Grounding conductor shall conform to Article 250 of the National Electric Code. <br /> C. All cable shall be manufactured with a distinctive marking on the exterior for its entire � <br /> length. This marking shall clearly specify the cable type with an "LS" suffix to identify <br /> Low Smoke rated cable. , <br /> D. Cable shall be installed through or parallel to studs, joists and rafters. Holes shall be <br /> drilled in the center of studs or joists wherever possible. Where not possible to drill in <br /> the center of studs or joists, a protective plate, such as Noer's "Safety Plate", shall be � <br /> installed to protect the cable from nails or screws. These holes shall be considered as <br /> cable supports. <br /> E. Support all cables with straps, cable ties or staples specifically designed for this ' <br /> purpose. Installation shall not cut or damage cable in any way. All damaged cable <br /> shall be immediately removed and replaced with new. Cable shall be supported within � <br /> 12" of each box, cabinet or fitting at intervals of 41/2 feet. <br /> F. A minimum of 6" of wire shall be exposed beyond the face of each device or j-box for <br /> terminations and/or device installation. Splice all ground wires per NEC. � <br /> G. Where required, cable or box connectors shall be two screw, strap type, specifically <br /> manufactured for connection NM or NMC cable to panels, cabinets or j-boxes. � <br /> H. The following manufacturers are approved for NM & NMC Cable: Bristol, Colonial, <br /> Encore, Excel, General and Southway. � <br /> END OF SECTION <br /> , <br /> , <br /> ' <br /> ' <br /> � <br /> RMAS CBA701 8/1/97 , <br /> 032497 16112 - 1 <br /> ' <br />