My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00009 - kitchen remodel
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
3020 North Shore Drive - 09-117-23-32-0003
>
Permits/Inspections
>
2015-00009 - kitchen remodel
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:49:38 PM
Creation date
10/17/2017 12:28:49 PM
Metadata
Fields
Template:
x Address Old
House Number
3020
Street Name
North Shore
Street Type
Drive
Address
3020 North Shore Dr
Document Type
Permits/Inspections
PIN
0911723320003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�p ; Bunkers & Associates LLC <br /> a structural engineers <br /> 6687 Forest Street <br /> Farmington, MN 55024 <br /> 651.366.2853 <br /> Date: September 28, 2014 <br /> To: Swan Architecture <br /> International Market Square <br /> 275 Market St. Suite 438 <br /> Minneapolis, MN 55405 <br /> Attn: James Arentson <br /> From: Eric Bunkers <br /> Project: Swenson Residence <br /> 320 North Shore Dr. <br /> Wayzata, MN 55391 <br /> Proj. No: 14237 <br /> Subject: Proposed Remodeling <br /> Dear James: <br /> As requested, we designed new structural members for the above referenced project. We have designed the <br /> new members using a roof and floor dead load of 15 psf, a roof snow load of 35 psf, and a floor live load of <br /> 40 psf in accordance with the Minnesota State Building Code. Our work only includes designing the new <br /> members as shown at the above reference project and is based on drawings provided by you and from our <br /> site visit. <br /> Attached are 2 framing sheets with annotated framing notes showing the new members and connections. All <br /> framing shall be shored and temporarily braced as required by the contractor and all minimum nailing shall <br /> be in accordance with IRC Table R602.3(1). Lumber shall be minimum #2 SPF with treated lumber to be#2 <br /> S. Pine and engineered lumber to have Fb =2600 psi with E = 1.9. Our calculations assume all lumber is of <br /> good quality and does not have large splits and checks and shall be visually inspected by the contractor at <br /> the time of construction. All fasteners in contact with treated lumber shall be G185 hot dipped galvanized or <br /> equal. Rebar shall be grade 60. Steel wide flange material shall meet ASTM A992. <br /> Concrete used for footings (4" slump) shall have a 28 day compressive strength of 3000 psi. The new <br /> footings have been designed as a typical spread footing based on a presumptive load-bearing value of 2000 <br /> psf in accordance with Table R401.4.1 of the IRC. The existing footings have been assumed to be typical <br /> spread footings on good soils that are assumed to be performing adequately. The contractor shall also verify <br /> the condition of structural members and foundations affected by the remodeling. Exterior grade shall slope <br /> away from the building and gutters with long downspouts should be used whenever possible. Foundation <br /> backfill shall be granular and well compacted. <br />
The URL can be used to link to this page
Your browser does not support the video tag.