Rhvac-Residential B,�.i�ht Commercial HVAC Loads Eiite Software�3evelopmer�t,li�c:
<br /> Sabre Plumbing�Heati"pg � 3017 Nor#h Sfiore Dr(3to�BL��
<br /> P m N 554�7 : _ Pa e 4
<br /> TotalBuildin Summa Loads
<br /> �a�r�r�t � ;�a � Lac �e�� �'��1
<br /> < a , .
<br /> �. . �..,
<br /> fle�i: or� �� ,x,. � � .` �� . �.�
<br /> Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 1333.4 35,969 0 37,568 37,568
<br /> SHGC,Window and Patio Door, u-value 0.31, SHGC
<br /> 0.29
<br /> 11J: Door-Metal-Fiberglass Core 35.6 1,856 0 512 512
<br /> R20 12F-Osw: Wall-Frame,Custom, R-20 Insulation in 6754 38,782 0 5,929 5,929
<br /> 2x6 Cavity, no board insulation, siding finish,wood
<br /> studs
<br /> RJ 20 Spray Foam:Wall-Frame, Custom, Rim Joist R-20 438 1,905 0 535 535
<br /> Closed Cell Spray Foam
<br /> R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 5860 11,726 0 6,470 6,470
<br /> Attic Floor(also use for Knee Walls and Partition
<br /> Ceilings), Custom, R-49 Blown Insulation, No
<br /> Radiant Barrier,Vented Attic,Asphalt Shingles
<br /> 22B-10pm: Floor-Slab on grade,Vertical board insulation 772 23,843 0 0 0
<br /> covers slab edge and extends straight down to 3'
<br /> below grade, any floor cover, R-10 insulation,
<br /> _ passive, heavy dry or light wet soil �� _i_________ � _ __�_��� _
<br /> Subtotals for structure: 114,081 0 51,014 51,014
<br /> People: 7 1,400 1,610 3,010
<br /> Equipment: 901 4,116 5,017
<br /> Lighting: 1750 5,968 5,968
<br /> Ductwork: 0 0 0 0
<br /> Infiltration:Winter CFM: 342, Summer CFM: 0 31,728 0 0 0
<br /> Ventilation:Winter CFM:284, Summer CFM:284 10,548 6,590 1,576 8,166
<br /> Humidification (Winter)38.51 gal/day : 14,122 0 0 0
<br /> AED Excursion: _ 0__, 0_ ___4,724 _`_4,724_
<br /> Total Building Load Totals: ^ 170,479 8,891 69,008 77,899
<br /> � � r
<br /> Total Building Supply CFM: 3,159 CFM Per Square ft.: 0.327 �
<br /> Square ft.of Room Area: 9,668 Square ft. Per Ton: 1,489
<br /> Volume(ft�)of Cond. Space: 101,116
<br /> #3 " .a ��. ;:;k. �� ,.�,
<br /> Total Heating Required Including Ventilation Air: � 170,479 Btuh 170.479 MBH
<br /> Total Sensible Gain: 69,008 Btuh 89 %
<br /> Total Latent Gain: 8,891 Btuh 11 %
<br /> Total Cooling Required Including Ventilation Air: 77,899 Btuh 6.49 Tons(Based On Sensible+Latent)
<br /> ,!M 5 '� _ c�� ..,a _ -
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's perFormance data at
<br /> your design conditions.
<br /> Monday,January 16,2017, 5:55 PM