My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Garden development project manual-1992
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2865 North Shore Drive - 09-117-23-24-0001
>
Misc
>
Garden development project manual-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:49:28 PM
Creation date
10/16/2017 3:18:43 PM
Metadata
Fields
Template:
x Address Old
House Number
2865
Street Name
North Shore
Street Type
Drive
Address
2865 North Shore Dr
Document Type
Misc
PIN
0911723240001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> PART 3 - EXECUTION � <br /> EXAMINATION � <br /> �xamine surfaces indicated to receive�avin�,with Installer present, for compliance with <br /> requirements for installation tolerances and other conditions affecting performance of unit pavers. � <br /> Do not proceed with installation until unsatisfactory conditions have been corrected. <br /> PREPARATION <br /> Vacuum clean concrete substrates to remove dirt,dust,debris,and loose particles. ' <br /> Remove substances from concrete substrates that could impair bond of mortar, includin�curing , <br /> and sealing compounds, form oil, and laitance. <br /> �ISTALLATION,GENERAL . � <br /> Do not use unit�avers with chips, cracks,voids,discolorations, and other defects that might be <br /> visible or cause staining in finished work. <br /> Cut unit�avers with motor-driven masonry saw equipment to provide clean,sharp,unchipped � <br /> edges. Cut units to provide pattem indicated and to fit adjoining work neatly. Use fiill units <br /> without cutting where possible. Hammer cutting is not acceptable. � <br /> Joint Pattem: As indicated below: <br /> �v unit�avers in joint}�attem shown. ` <br /> Handri� t Joints: Where unit pavers are indicated without spaced joints,set unit pavers with <br /> hand-tight joints. � <br /> �paced Joint Widths: Where brick flooring is indicated with spaced joints 5lled with grout, <br /> comply with the following requirement: • , <br /> Provide nominal joint width of 3/8 inch with variations not exceeding plus or minus 1/16 <br /> inch. <br /> Tolerances: Do not exceed 1/16-inch unit-to-unit offset from flush(lippage) and a tolerance of 1/8 � <br /> inch in 2'-0" and 1/4 inch in 10'-0"from level or slope as indicated,for finished surface of paving. <br /> UNGROUTED MORTARLESS BRICK PAVER APPLICATIONS � <br /> Place aQQre�ate base and subbase in thiclrnesses indicated. Compact by tam}�ing with plate � <br /> vibrator and screed to depth required to allow for setting of brick pavers. <br /> Place sand levelin�bed where indicated. Compact by tamping or wetting and screed to depth <br /> indicated or required to allow for setting of brick pavers. � <br /> �et brick�avers in�attern indicated,placing as closely together as possible. Sweep fine sand over <br /> surface to fill joint irregularities. � <br /> SECTTON 02515-UNTT PAVERS , <br /> Page 4 of 6 <br /> � <br />