My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Irrigation well project manual-1992
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2865 North Shore Drive - 09-117-23-24-0001
>
Misc
>
Irrigation well project manual-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:49:28 PM
Creation date
10/16/2017 3:04:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2865
Street Name
North Shore
Street Type
Drive
Address
2865 North Shore Dr
Document Type
Misc
PIN
0911723240001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' <br /> PART 2: PRODUCTS <br /> 2.01 LIGHTING LOAD CENTERS ' <br /> A. Load centus shall be surface mo�nted.Load centers mounted on uninsulatsd masonry walls shall , <br /> be mounted on 1/l inch spacers. 'Ilie bussing shall be suitable for 200 amperes,minimum. The <br /> number of circuits shall be not less than shown on the schedules shovm on the drawings. Load <br /> center shall be NEMA 1, bear the LTL label. and be listed as "suitable for use as service ' <br /> equipment". , <br /> g, Cabinet rough-in brnces shall be code gauge stcel, zinc galvanized on both inside and outside , <br /> s�ufaces,with an iaauned t]ange a�all sides of the front The front covers shall be sheet stcel, <br /> with a nist inhibltar prima and a balced ena�nel finish for s�rface mounted centers. The front <br /> covers shall be fittsd with a door. ' <br /> C. Load center bussing shall be braced at least eq�al to the intem�pting rating of the main <br /> overcurrent device. The losd ca►ter neuual shall have solderless connectors numbered not less , <br /> thaz►the numbu of branch circuits and available spaces in the load center. All spaces shall be <br /> suitable m receive branch circuit breakers. Adjacent breakers shall be connected to alternate <br /> P�• , <br /> D. Unless otherwise definod,main circuit breakers rated at 240 volts shall have an interrupting rating <br /> of not less than 10,000 amps,r.m.s.,sym.,and branch breake.rs shall have an interrupting rating ' <br /> of not less than 10,000 amps, r.m.s., sym. Circuit breakers shall indicate open, closed,or trip <br /> conditions by handle position. Circuit breakers shall be quick-make.quick-break with thermal- � <br /> magnetic trips having long-time and instantaneous tripping characte,ristics. Muld-pole breakers <br /> shall have one handle with handle tie a internal tirip bar with the circuit breaker cases fastened <br /> together. ' <br /> E. Where requind, the load cu►tecs sl�all cantain gro�nd fault interrupting circuit breakers. The <br /> brPakers stiall have an intetrupting rating of not less than 10,000 amps,r.m.s.,sym. The breakers , <br /> sl�all have a sensing circuit capable af tripping the breaker in not more than 30 m.s.at a curnent <br /> inbalance of S m.a. Tl�e breaker shall contain a sensing circnit test feawre. <br /> F. Install cbsu�e pla�es in each space not occupied by a bnaker wh�e the knockout has been ' <br /> ramoved. Accurately list the circuit numbas ai the load center schedule. Fill out the schedule <br /> ntilizing a typ�writa o�block letteis. ' <br /> 2.02 GROUNDING MATERIALS <br /> wi e National Electrical Code and as ' <br /> A The entire u�stallahon shall be gronnded m accordattce th th <br /> o�����. r <br /> � <br /> TS-5-3-2 , <br /> � <br />