Laserfiche WebLink
• Page 1 of 2 <br /> Melanie Curtis <br /> From: Jensen, Matthew D [mattjensen@bonestroo.com] <br /> Sent: Thursday, June 29, 2006 9:10 AM <br /> To: Melanie Curtis <br /> Cc: Kellogg, Tom P <br /> Subject: RE: 2545 North Shore Drive Retaining Wall -Review for Code Compliance <br /> Hi Melanie, <br /> I spoke with]erry King, the engineer of record, yesterday. I also received a copy of the fax with the <br /> certification. The certification addresses my original Items 1 &2. Item 3 is not required per IBC Section 1804, <br /> specifically Table 1804.2. <br /> Please have the Building Inspector verify the soils meet IBC Section 1804 once the wall is excavated. <br /> If there are any questions, please give me a call. <br /> Thanks, <br /> Matt <br /> Matthew D.Jensen, P.E. <br /> Bonestroo Rosene Anderlik&Associates,Inc. <br /> 2335 West Highway 36 St.Paul,MN 55113 <br /> Phone: (651)604-4835 <br /> Fax: (651)636-1311 <br /> Cell: (651)775-5639 <br /> From: Melanie Curtis [mailto:MCurtis@ci.orono.mn.us] <br /> Sent: Wednesday, June 28, 2006 2:09 PM <br /> To: ]ensen, Matthew D <br /> Subject: RE: 2545 North Shore Drive Retaining Wall - Review for Code Compliance <br /> Hi Matt—I assume by now the engineer has called you regarding these plans. He faxed me something with a <br /> signature on it... did you receive this too? Also will you please update me as to whether or not his questions <br /> about the geotechnical engineering met your specifications...? Thanks, Melanie <br /> -----O�iginal Message----- <br /> From: Jensen, Matthew D [mailto:mattjensen@bonestroo.com] <br /> Sent: Monday, June 26, 2006 6:01 PM <br /> To: Melanie Curtis <br /> Cc: Kellogg,Tom P <br /> Subject: 2545 North Shore Drive Retaining Wall - Review for Code Compliance <br /> Melanie, <br /> I have reviewed the permit application for the above referenced address to construct a retaining wall on <br /> the property. Using the International Building Code (2000), the submittal should contain the following <br /> revisions or additional information: <br /> 1. The submittal should provide construction plans showing plans, elevations, sections, details, and <br /> specifications signed by a registered professional engineer. <br /> 2. The wall design needs to be signed by a registered professional engineer. <br /> 3. The soil bearing capacity is assumed. This assumption should be verified by a geotechnical <br /> engineer. <br /> 6/29/2006 <br />