Laserfiche WebLink
� � � � � � � � � � � � � � � � � � � <br /> Insulating the Window Installation <br /> NOTE.� We recommend two possible ways of insulating the RO cavity. Both methods follow the principle that stopping air intrusion will aid in managing water <br /> intrusion into the RO. The first method uses a combination of one bead of low expansion/low compression/closed cell foam at the exterior plane of the RO in <br /> conjunction with loose fill fiberglass insulation. The second method uses two beads of low expansion foam (one at the exterior plane of the RO and another at <br /> the interior plane of the RO). <br /> ri;�..., ��. <br /> :� �� ,�.� <br /> � .�. <br /> � � ��, - " � <br /> I ~ � � �� <br /> �' ;�„ ..._--.�.--,- �� � <br /> �� �. ��° <br /> ��, �t ���� ,� . <br /> � <br /> � i i - <br /> a,. . .� <br /> � w � <br /> �,a �. �! � <br /> �� � Minimal expansion foam- <br /> r filled behind backer rod and <br /> �`�� �� � � �_ � Loose fll fberglass <br /> � � ��`e'�� { at the corners over the sill insulation <br /> �° �r_ <,--� � �� sealant line <br /> n„� ;� � <br /> � ,• <br /> ���,` ` a 3 {�a`�."��`� �_ _ — <br /> / <br /> ___ _ _ —_ — <br /> ��a ��'��� � �� —� � � ��i i � � / <br /> ��;.�, � �� � �� Backer Rod � � ;'•� � � <br /> : � /� � . / <br /> � <br /> - <br /> 3. E; � .. _ � ���. <br /> Fa ��cy�{ �� q <br /> �� �.� �' , / � . <br /> ;¢. ��� � m ;, <br /> ~ ` r...- �; ��'� <br /> .. o. c �"'ah <br /> I � <br /> . Y / c s <br /> ' . ._Y. . ' . ; <br /> II <br /> r . ' . ..+��-�+^ I <br /> ' - � � � ` 4 2}e,a -e.�. ..� , .� <br /> � �€ � �. . . � � .ae",�" ���� ;a' <br /> s �. � � �� � . v a.. <br /> � ` � � �}', , ,�<, : <br /> m � � � � �� .; � �� <br /> ���� v � <br /> , � �„ <br /> � � I <br /> ��� � � �. <br /> . <br /> � I , �� , �x <br /> � � y � ; _ � ,; ` <br /> i �, ' ; <br /> I v ,i ;� <br /> � � �. <br /> �� .. <br /> � ' � <br /> , <br /> �� <br /> a <br /> , _. „ ' �-^� _, u,�y;��,: a.� .a ; ..,�`'.F <br /> �', . � , .s,... . , ,^ ,�»,. .< <br /> ����`• �,. � ���a <br /> � . � .���--��i (b��.� x � ` ���..:_ ° � �, � <br /> ,_�a�_�. .._ ��, � �� �� <br /> __ �� �_ <br /> _ __ _�---- a ��_ _ _ __ � �� � <br /> _ � <br /> Figure 6 Insulating the RO using a combination of minimal expansion foam and loose fill insulation(Method 1) <br /> Insulating the RO (Method 1) 2. Apply one bead of minimal expansion, low 4. When the low expansion foam has set, fill the <br /> 1. Insert backer rod around jambs and head compression, closed cell foam against the cavity with loose fill fiberglass insulation. See <br /> jamb. Push backer rod to the back of the backer rod. See figure 6b. figure 6c. <br /> cavity so it contacts casing or nail fin (or in the <br /> case where neither are used, exterior flashing 3. Fill the bottom corners with foam out to the sill <br /> material). See figure 6a. sealant line. See figure 6b. <br /> 2012-03-07 $ Window Rough Opening Prep and Flashing <br /> 19913776 Method A1 -Membrane Drainage System <br />