My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995-007235 - new septic
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2425 North Shore Drive - 09-117-23-44-0003
>
Septic
>
1995-007235 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:29 PM
Creation date
10/5/2017 12:40:13 PM
Metadata
Fields
Template:
x Address Old
House Number
2425
Street Name
North Shore
Street Type
Drive
Address
2425 North Shore Dr
Document Type
Septic
PIN
0911723440003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S�P _TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE � St. Michael, MN 55376 • (612) 497-3566 <br /> E� � <br /> � <br /> ,�� September 20 , 1994 <br /> Morris Levy <br /> 2425 North Shore Drive <br /> Orono, Henn. Co. , Mn <br /> This On-Site Sewage Treatment System is Designed for a Type 1, four <br /> bedroom home Designed in accordance with the Minnesota Pollution <br /> Control Agency Chapter 7080 and local ordinances . <br /> This site has an existing failing system with surface discharge. <br /> The existing tanks may be used upon approval by the local Inspector. <br /> The tanks must be water tight or will need to be abandoned, pumped <br /> & filled with soil . Approval will be needed for the existing tanks <br /> to be 50 ' from a wetland or if new tanks are installed, 35 ' from <br /> a wetland. The pumping chamber will need approval for 50 ' . <br /> The soils on this site are a loamy sand . A seasonally high water <br /> table was located at 86" , (mottled soil ) . The bottom of the <br /> system must be located at least 3 ' above the seasonally high <br /> water table . A 5tandard Trench System may be installed. <br /> The soils at a depth of 30" have a percolation rate averaging <br /> . 7 min/inch. <br /> Each trench will need to be over excavated a minimum of 12" and be <br /> replaced with uncompacted loamy sand. This liner is needed to slow <br /> the effluent down for treatment. If drop boxes are used with a <br /> minimum of four trenches, this liner is not needed. Recommend drop <br /> boxes . <br /> A pumping chamber wi11 need to be installed to lift the effluent <br /> to the treatment area. <br /> The power supply and switches must be located outside the mar►hole <br /> and pumping chamber in a we.ather proof enclosure. A warning device <br /> must be installed with a light and sound device, this is in case of <br /> a pump failure . (mercury floats are a good method) . <br /> All neighboring wells are located greater than 100 ' away from the <br /> proposed treatment area . <br /> CONT ' D <br />
The URL can be used to link to this page
Your browser does not support the video tag.