My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
material/test certificate/aboveground piping
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2240 North Shore Drive - 10-117-23-32-0019
>
Misc
>
material/test certificate/aboveground piping
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:26:23 PM
Creation date
10/4/2017 12:31:53 PM
Metadata
Fields
Template:
x Address Old
House Number
2240
Street Name
North Shore
Street Type
Drive
Address
2240 North Shore Drive
Document Type
Misc
PIN
1011723320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> 2of3 <br /> OPERATION ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC <br /> PIPING SUPERVISED ❑ YES ❑ NO DETECTING MEDIA � YES ❑ NO <br /> SUPERVISED <br /> DOES VALVE OPERATE FROM THE MANUAL TRIP,REMOTE,OR BOTH <br /> CONTROL STATIONS? ❑ YES ❑ NO <br /> DELUGE AND �S THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR �F NO,EXPLAiN: <br /> PREACTION <br /> TESTING? <br /> VAWES ❑ YES ❑ NO <br /> DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAXIMUM TIME TO <br /> MAKE MODEL SUPERVISON LOSS ALARM? OPERATE VALVE RELEASE? OPERATE RELEASE <br /> WA YES NO YES NO MIN SEC <br /> ,.,�. <br /> PRESSURE LOCATION MAKE SETTING �AT1C PRESSURE RESIDUAL PRESSURE FLOW RATE <br /> REDUCING &FLOOR 8 MODEL (FLOWING) <br /> VALVE TEST INLET OUTLET INLET oUTLET FLOW RATE <br /> PS SI PSI PSI <br /> N/A <br /> HYDROSTATIC: Hydrostatic tesfs shali be made at not less than 200 psi(13.6 bars)for 2 hours or 50 psi(3.4 bars) <br /> above static pressure in excess if 15Q psi(10.2 bars)for 2 hours. DiffereMial dry-pipe vaAre dappers shall be left <br /> TEST �n during the test to pre�rent damage. All aboveground piping leakage shall be stopped. <br /> DESCRIPTION pNEUMATIC: EstaWish 40 � 2.7 bars air <br /> ps'( ) pressure and measure drop,which shall not exoeed 1'/z psi(0.1 bars) <br /> in 24 hours. Test p�essure tanks at normat water level and air pressure and measure air pressure drop,which shall <br /> not exceed 1'r4 psi(0.1 bars)in 24 hours. <br /> ALL PIPING HYDROSTATICALLY TESTED AT: 1F NO,STATE REASON: <br /> 20o PSI ( BARS ) FOR 2 HOURS <br /> DRY PIPING PNEUMATICA�LY TESTED � YES ❑ NO <br /> EQUIPMENT OPERATES PROPERLY � YES ❑ NO <br /> DO YOU CERTIFY AS THE SPRlNKLER CONTRACTOR THAT ADDITNES AND CORROSIVE CHEMICALS, <br /> SODIUM SILICATE OR DERIVATIVES OF SODIUM SIUCATE,BRINE,OR OTHER CORROSIVE CHEMICALS <br /> WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? <br /> �YES ❑ NO <br /> TESTS READING OF GAUGE IOCATED NEAR RESIDUAL PRESSURE WtTH VALVE IN TEST <br /> DRAIN WATER SUPPLY TEST CONNECTION: CONNECTION OPEN WIDE: <br /> TEST � pSl ( BARS ) PSI ( BARS ) <br /> UNDERGROUND MAINS AND I.EAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE <br /> CONNECTION MADE TO SPRINKLER PIPING <br /> VERIFIED BY COPY OF THE U FORM NO.858 ❑ YES � NO OTHER,EXPLAIN: <br /> FLUSHED BY INSTALLER OF UNDERGROUND � yES �.NO WA-P�ssure Tank <br /> SPRINKLER PIPING � <br /> BLANK NUMBER USED LOCATIONS NUMBER REMOVED <br /> TESTING <br /> GASKETS <br /> WELDED PIPING � YES ❑ NO <br /> IF YES... <br /> DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING � � <br /> PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST <br /> AWS D10.9,LEVEL AR-3? YES NO <br /> WELDING �YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS � � <br /> QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST YES NO <br /> AWS D10.9,LEVEL AR-3? <br /> DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIAMCE <br /> WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO � � <br /> ENSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE YES NO <br /> SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, <br /> AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? <br /> CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO � ❑ <br /> (DISCS) ENSURE THAT ALL CUTQUTS(DISCS}ARE RETRIEVED? YES NO <br /> 1996 Edition <br />
The URL can be used to link to this page
Your browser does not support the video tag.