s <br /> 2of3 <br /> OPERATION ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC <br /> PIPING SUPERVISED ❑ YES ❑ NO DETECTING MEDIA � YES ❑ NO <br /> SUPERVISED <br /> DOES VALVE OPERATE FROM THE MANUAL TRIP,REMOTE,OR BOTH <br /> CONTROL STATIONS? ❑ YES ❑ NO <br /> DELUGE AND �S THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR �F NO,EXPLAiN: <br /> PREACTION <br /> TESTING? <br /> VAWES ❑ YES ❑ NO <br /> DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAXIMUM TIME TO <br /> MAKE MODEL SUPERVISON LOSS ALARM? OPERATE VALVE RELEASE? OPERATE RELEASE <br /> WA YES NO YES NO MIN SEC <br /> ,.,�. <br /> PRESSURE LOCATION MAKE SETTING �AT1C PRESSURE RESIDUAL PRESSURE FLOW RATE <br /> REDUCING &FLOOR 8 MODEL (FLOWING) <br /> VALVE TEST INLET OUTLET INLET oUTLET FLOW RATE <br /> PS SI PSI PSI <br /> N/A <br /> HYDROSTATIC: Hydrostatic tesfs shali be made at not less than 200 psi(13.6 bars)for 2 hours or 50 psi(3.4 bars) <br /> above static pressure in excess if 15Q psi(10.2 bars)for 2 hours. DiffereMial dry-pipe vaAre dappers shall be left <br /> TEST �n during the test to pre�rent damage. All aboveground piping leakage shall be stopped. <br /> DESCRIPTION pNEUMATIC: EstaWish 40 � 2.7 bars air <br /> ps'( ) pressure and measure drop,which shall not exoeed 1'/z psi(0.1 bars) <br /> in 24 hours. Test p�essure tanks at normat water level and air pressure and measure air pressure drop,which shall <br /> not exceed 1'r4 psi(0.1 bars)in 24 hours. <br /> ALL PIPING HYDROSTATICALLY TESTED AT: 1F NO,STATE REASON: <br /> 20o PSI ( BARS ) FOR 2 HOURS <br /> DRY PIPING PNEUMATICA�LY TESTED � YES ❑ NO <br /> EQUIPMENT OPERATES PROPERLY � YES ❑ NO <br /> DO YOU CERTIFY AS THE SPRlNKLER CONTRACTOR THAT ADDITNES AND CORROSIVE CHEMICALS, <br /> SODIUM SILICATE OR DERIVATIVES OF SODIUM SIUCATE,BRINE,OR OTHER CORROSIVE CHEMICALS <br /> WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? <br /> �YES ❑ NO <br /> TESTS READING OF GAUGE IOCATED NEAR RESIDUAL PRESSURE WtTH VALVE IN TEST <br /> DRAIN WATER SUPPLY TEST CONNECTION: CONNECTION OPEN WIDE: <br /> TEST � pSl ( BARS ) PSI ( BARS ) <br /> UNDERGROUND MAINS AND I.EAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE <br /> CONNECTION MADE TO SPRINKLER PIPING <br /> VERIFIED BY COPY OF THE U FORM NO.858 ❑ YES � NO OTHER,EXPLAIN: <br /> FLUSHED BY INSTALLER OF UNDERGROUND � yES �.NO WA-P�ssure Tank <br /> SPRINKLER PIPING � <br /> BLANK NUMBER USED LOCATIONS NUMBER REMOVED <br /> TESTING <br /> GASKETS <br /> WELDED PIPING � YES ❑ NO <br /> IF YES... <br /> DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING � � <br /> PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST <br /> AWS D10.9,LEVEL AR-3? YES NO <br /> WELDING �YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS � � <br /> QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST YES NO <br /> AWS D10.9,LEVEL AR-3? <br /> DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIAMCE <br /> WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO � � <br /> ENSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE YES NO <br /> SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, <br /> AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? <br /> CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO � ❑ <br /> (DISCS) ENSURE THAT ALL CUTQUTS(DISCS}ARE RETRIEVED? YES NO <br /> 1996 Edition <br />