Concrete strength report
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2240 North Shore Drive - 10-117-23-32-0019
>
Misc
>
Concrete strength report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:26:22 PM
Creation date
10/4/2017 12:01:10 PM
Metadata
Fields
Template:
x Address Old
House Number
2240
Street Name
North Shore
Street Type
Drive
Address
2240 North Shore Drive
Document Type
Misc
PIN
1011723320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIELD MORTAR STRENGTH REPORT �ME co„s„�ta�ts, ���. <br /> Project and Location: Minnetonka Center for the Arrs v�ayzata Minne��+a 14000 21st Avenue North <br /> Architect/Engineer: James Dayton De�ian Minneapolis,MN 55447 <br /> General Contractor: M.A. Mortenson Com anv Ph. (763)559-1859 <br /> Masonry Contractor: M.A. Mortenson Com a�nvr Fax(763)559-0720 <br /> Mortar Supplier. <br /> Owner/Develo er: GME Project Number: 9256-A <br /> DATE CAST TEMPERATURE <br /> DATE AGE CROSS COMPRESSIVE <br /> SET NUMBER DATE RECENED CONE PENETRATION SECTIONAL MAXIMUM LOAD STRENGTH <br /> LOCATION OF MORTAR PLACEMENT mm AIR% MIX Q F) AIR Q F) TIME TESTED (da s • <br /> y� AREA in� Ibs-force si <br /> M1-A 7/25/01 Type S Mortar 75 75 9:00 8/2 8 3.14 13600 4330 D <br /> M1-B 8/1/01 Above Grade,CMU Wall 8/22 28 3.14 12700 4040 D <br /> M1-C Elevator Shaft 8/22 28 3.14 14700, � 4680 C <br /> Grid 10,Grid K <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field Specified Strength of Laboratory Prepared Mortar: <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens Type M:2500 psi <br /> ASTM C 109 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars(Using 2"Cube Type S: 1800 psi <br /> Specimens) Type N:750 psi <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method Type O: 350 psi <br /> ASTM C 231 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 270 Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens <br /> ASTM C 496 Standard Specification for Mortar for Unit Masonry "The test results obtained under this test method are not required <br /> ASTM C 780 Standard Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and to meet the minimum compressive values in accordance with the <br /> Reinforced Unit Masonry property specification in ASTM C 270." ASTM C 780.1.3 <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> Date Report Prepared: <br /> Test specimens were cast by GME Consultants, Inc. August 7,2001 <br /> -+ Test specimens were not cast by GME Consultants-No other information is available • August 23,2001 <br /> � -� Test specimens were cast in 2"x 4"molds with a cross-sectional area of 3.14 in2 <br /> Test specimens were cast in 3"x 6"molds with a cross-sectional area of 7.07 in2 <br /> Test specimens were cast in 2"cube molds with a cross-sectional area of 4 inz <br /> Copies To: Types of Fracture ASTM C 39 <br /> • Mr.Steve Blaser-M.A.Mortenson Company --- --- — <br /> ---- �--- <br /> • Mr.Mark Strelnieks-M.A.Mortenson Company <br /> • Mr.James Dayton-James Dayton Design <br /> , :. ., ,.. : •, <br /> ammy A.Ha an o , . . <br /> ` ' �� Senior Project Engineer <br /> � .Cone Cone anA SpM Cone and Shear Shear Columner <br /> (a) (b) (c) (A) (e) <br />