My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Concrete strength report
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2240 North Shore Drive - 10-117-23-32-0019
>
Misc
>
Concrete strength report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:26:22 PM
Creation date
10/4/2017 12:01:10 PM
Metadata
Fields
Template:
x Address Old
House Number
2240
Street Name
North Shore
Street Type
Drive
Address
2240 North Shore Drive
Document Type
Misc
PIN
1011723320019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AELDER AND WELDING OPERATOR QIIALIFICATION TEST RECORD <br /> REPORTED TO: Western Steel Erection DATE: March 23 , 1990 <br /> Attn: Herman McClellan <br /> PO Box 575 <br /> Long Lake, MN 55356 <br /> Welder or Welding operator' s name Neal Ramlow <br /> Identification No. <br /> F�elding Process S�W Manual x Semiautomatic Machine <br /> Positi��n 3G (Vertical Up) and 4G (Overhead) <br /> (Flat, Horizontal, Overhead, or Vertical -If Vertical, state uhether upuard or downuard) <br /> In acc��rdance with procedure specification no. n/a <br /> Nlateri��l Specification ASTM:A36 <br /> Diametf�r and �ti'all Thickness �1f plpe) -otheruise, Joint Thickness l . 00�� <br /> Thicknf�ss Range this qualifies 0 . 125" to Unlimited <br /> FILLER METAL <br /> Specification No. AW S A 5 . 1 Classification No. E 7 0 1 8 F No. 4 <br /> Describe filler material (tf not covered by AWS Specification) ri/a <br /> Is Backing Strip usedl Y@ S <br /> Filler Metal Diameter and Trade Name 1/8�� - <br /> Flu�c for Su�erged Arc or gas fcr Gas Metal Arc or Flux Covered Arc Llelding I1/d <br /> VTSUAL INSPECTION (9 . 25 . 1) <br /> App�arance_ S3t1SfaCtOY'V U�ercut Satisfactorv Piaing Pcrosity Satisfactorv <br /> GUIDED BEND TEST RESULTS <br /> Type Result <br /> 3G-1 Side S3'isfactcrv <br /> 3G- Side i f r <br /> 4G-1 Sid i f r <br /> 4G-2 Sid� Satisfactorv <br /> FILLET TEST RESULTS <br /> Appearance_ri1 d Fillet Size <br /> Frac[ure Te�ct Root Penetration Macroetch <br /> (D=scribe th�e location, nature arx; size of any crack er tearing of the specimen.) <br /> RADIOGRAPHIC TEST RESULTS <br /> Film Idencificatien IResults Remarks <br /> n/a I <br /> Test w tnessed by WESTERN STEEL ERECTION Test no. <br /> pe r <br /> sarr�les tested by: TWI CITY T STING COP.PORP.TION �aboratory test ro. 4142 90-070%h <br /> � <br /> Fef 7est date M3r'Ch 20 , 1990 <br /> ue, the urxiersigned, certify that the statements in this record are correct and that Welds uere prepared and tested in accordance <br /> with the req��irements of 5C or p of A11S D1.1, 1988, Structural Uelding Code. <br /> Manufacturer or co�tractor WESTERN STEEL ERECTION <br /> O Authorized by /(i�'�OfI VL�G/� � <br /> Date y�/e/90 <br />