Laserfiche WebLink
CONCRETE STRENGTH REPORT GME Consultants,���. <br /> Project and Location: Minnetonka Center for the Arts.Wayzata. Minnesota 14000 21st Avenue North <br /> ArchitecUEngineer: James DaXton Design Minneapolis,MN 55447 <br /> General Contractor: M:A. Mortenson CompanX Ph. (763)559-1859 <br /> Concrete Contractor: M.A. Mortenson CompanX Fax(763)559-0720 <br /> Own�r/Developer: <br /> "i' GME Project Number: 9256-A <br /> • 1 CON UPPLIER` Aggregate Induslries PLANT: 1 MIX: H407A7 CUMULATNE OUANTITYc 10/70/56 YDS <br /> � r`e; ---- <br /> �c �+�>� SPECIFIED <br /> V SLUMP(inch): <br /> � ~ MIX WAS PLASTICI2ED: 7" SPECIFIED AIR CONTENT(%): �% REQUIRED STRENGTH AT 28 DAYS: 4000 pSl <br /> ��' DATE CAST SLUMP(inch) TEMPERATURE <br /> �J`� OATE BEFORE AFTER DATE AGE CYL Wf. MAX LOAD(Ibs- COMPRESSIVE <br /> SET NUMBER RECEIVED LOCATION Of CONCRETE PLACEMENT P�'°'STICIZER PLAST�CIZER AIR% MIX P F) AIRQ F) TIME TRUCK# TESTED (days) (Ibs) �a�) STRENGTH si PASS Y/N ' <br /> 15A 7/23/01 West Wall 7 7.4 85 90 4:00 165 7/30 7 29.1 119500 , �t�30 D <br /> 15B 7/24/01 8/20 28 29.1 155900 5510 Y C <br /> 15C 8/20 28 29.3 160300 5670 Y C <br /> 15D sp <br /> Date Report Prepared: <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field .lUly 30, 2001 <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Test Specimens <br /> ASTM C 94 Standard Specification for Ready-Mix Concrete <br /> ASTM C 138 Standard Test Melhod for Unit Weighl,Yield 8 Air Content(Gravimetric)of Concrete AUgUSt 20, 2001 <br /> ASTM C 143 Standard Test Method for Slump of Hydraulic Cement Concrete <br /> ASTM C 172 Standard Practice for Sampling Freshly Mixed Concrete <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Melhod <br /> ASTM C 231 Standard Test Method for Air Contenl of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> � Test specimens were cast by GME Consultants,Inc. <br /> Test specimens were not cast by GME Consultants-No other information is available <br /> •. Test specimens were cast in 6"x 12"molds net cross-sectional area of 28.27 inZ unless otherwise noted. <br /> Copies To: Types of Fracture ASTM C39 . <br /> • Mr.Steve Blaser-M.A.Mortenson Company --- <br /> __-.__ --- ----- --- <br /> � Mr.Mark Strelnieks-M.A.Mortenson Company <br /> • Mr.JamesDayton-James Dayton Design . :i <br /> • Concrete Supplier Tammy A.Hakanson,P.E. <br /> ���� co„ e,„,5,,,;,�,,,,,,,,,,,5,,�„, s,,,,e, coh��,��, Senior Project Engineer <br /> (al 1�1 (c) (e) (�) <br />