My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire protection info
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2180 North Shore Drive - 10-117-23-31-0098
>
Misc
>
Fire protection info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:24:56 PM
Creation date
10/3/2017 12:45:15 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
North Shore
Street Type
Drive
Address
2180 North Shore Drive
Document Type
Misc
PIN
1011723310098
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10/24/97 FRI 16:04 FA% � w GOETSCH �021 <br /> , - <br /> Sequence of Operations FT,,q� <br /> Jockey Pump Controller 500 <br /> � <br /> �n�rRovucno,v <br /> The purpose of the jockey pump control- 2. For automatic operation with a minimum ru�, <br /> ler and jockey pump is to boost small volume period. controllers are provided with function <br /> drops in pressure with a sma11 pump to avoid TR, an adjustabie timing device located atop <br /> unnecessary cycfing of a large fire pump. contactor M, which will be held energized fo��a <br /> preset time. The purpose of the�ming device <br /> 1. The jockey pump controller selector is to eliminate unnecessary cyciing of the <br /> switch (H-O-A) allows the conVoller to be jockey pump for smali pressure changes. <br /> pre-set as follows: Some controllers may provide the timing <br /> A. Manual in "H" hand. function by means of a separate relay, TR, and <br /> B, Off in "O". timed timing head contacts TR to hold <br /> C. Automatic operadon in the "A"posi- contactor M energized for a pre-set time eve� <br /> tion. though the pressure has been restored. <br /> MANUAL OPERATION 3. 8ranch circuit conductor protection may be <br /> Upon switching from "O"to "H�, the M provided by line fuses 1� 2, 3 FU o�by a circuit <br /> contactor coil will electrically be energized breaker depending upon conflguration. <br /> closing M contacts on L1A, L2A, L3A, start- <br /> ing and running the motor. The motor will 4, Various options such as controt arcuit opera- <br /> continue to run unless there occurs: tion from low voltage cantrol circuit transformer <br /> A. A major fault opening fuses 1, 2, 3 T1, may be selected. Qther modifications such <br /> FU. as pilot lights and alarms may be added de- <br /> a. A motor overload opening normally pending upon customer selectiens. <br /> closed contacts OL on wi�e 6. The <br /> overload relay will remain tripped unti( <br /> manually reset after clearing the <br /> overload condition. <br /> C. The main selector switch is returned <br /> to 'O"for off. <br /> AUTOMATIC OPERATION <br /> 1. Automatic operation is the same except <br /> that the pump motor contactor M is <br /> energized by a drop in pressure sensed <br /> by pressure switch PS. <br /> . riretrol; Inc. <br /> s Industria/ Contro! Div�sion 0� <br /> 10fi MacKenan Drive• P.O. Bvx 9000•Cary, NC 27512• FAX (919) 460-5250�(919�460-5200 <br />