Laserfiche WebLink
, --o� . <br /> � � <br /> : O O�; <br /> ���I � . ''`� C ITY of ORONO <br /> ,..}a,r;;l � <br /> �, ��!� ;�;; YI�\f� �. ,�l� Municipal Offices <br /> ,� :;� :;�:.. �,�,°-;;,, , <br /> .t " '�' �:;'•,`:`:�;�G Street Address: GSa-a�-}q-y6o 0 <br /> Mailing Address: <br /> �kE8H�4' 2150 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323- 66 <br /> To Current Owner: Address: �� � � (�1 ��� r�``f� ��° <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and conshvction standards ofthe current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cunent Orono <br /> Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or eazlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stanchrds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soi!or sand between the distribution device and the lirniting soil characteristics. <br /> TANK CONDITION(5-7): ' <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years, <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped throuQh manhole and not throush white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron fiiter discharge out of septic svstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workin¢in your house. The alarm warns owner that septaee is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : C6 <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: D�`'`���'.e� J �4��5 �1�-, � �c_ Y��C.� ��:.5 ��i�� �r <br /> � t G��--�'r S �"` L v� C 2` a � MC�I� , <br /> �=7 �a� ��� <br /> Date of Inspection Matt Bolterman - Septic System Inspector • <br /> , y <br /> Note: ln the event that this inspection report is used to satisfy the requirements for a mortgage or otlter transfer of property, be advised chat this report does <br /> nu� guarantce or certif}• that an e�isting system �vill continue to function properl}•, but is merely an opinion of the adequacy of the system under cuRent <br /> cunditions based on die available inforniation. <br />