Laserfiche WebLink
�°� _ <br /> o , o <br /> �-=��g �� � C ITY of ORONO <br /> ,����f�,_y � <br /> < ��� <br /> � � �� ���y'��,�.� ��15r Municipal offices <br /> � ��'�,��-7�r��� � SVeet Address: Mailin�Addross: <br /> �EggOg' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> f <br /> Owner: Address: 1749 North Farm Rd. <br /> Permit #'s: 214 D tes: 9/22/87 Contractors: Clover Hill Co. <br /> (This is [�] an existing system [ ] new construction) . <br /> STEM COMPLIANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operatinq properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be desiqned, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [�j or is not [ ] identified under this aeptic syatem. If the <br /> aaturated soil level is not identified, this clasaification is subject to revision.) <br /> K CONDITION (5-9) : 5 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [�] or are not [ ] water tiqht or the condition is [ ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> �D CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : loo► <br /> CON7NIENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 3.5 feet and the system is compliant. <br /> � ✓�� <br /> Date of Inspection Se System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a , <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />