Laserfiche WebLink
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Otfice Box 66 <br /> Crystal Bay, MN 55323-0066 a � ON—SITE 3EWA(�L TREATI�NT <br /> INSPECTION REPORT <br /> ti <br /> ti <br /> ��9k o4�G <br /> EsH <br /> Owner• � �iU� Address: � • <br /> Permit #�'s: �� Dates:_ L���1 Contractors: r <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected end appears to fall into the category <br /> checked below. <br /> (This is f,,� an existing system [ ] new construction) <br /> S STEM CONFORMITY 1-3 : <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewege input <br /> without discherging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet atl the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which �y or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil charecteristic [�has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDIT[ON (5-10): <br /> T� inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be punoed out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is et a critical level. Tanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar$e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each <br /> tank at next p�n�out. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is lxated directly over tank beffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION C11-14): <br /> D�field inspection indicates: <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated end visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (sloce,setbacks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table,etc.): <br /> COMMENTS: <br /> Date of Inspection p ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortg_ e or other transfer of <br /> property, be advised that this report does not guarantee or cert�fy that an existing system w�l continue to f�ti� <br /> properly� but is merely an opinion of the adequecy of the system under current conditions based on the available <br /> informat�on. <br /> . This report must be kept on the premises with the system locetion and Fxanping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />