Laserfiche WebLink
� °� � <br /> o :,. o <br /> ��-� �-��� CITY of ORONO <br /> 'a��r��� �+ <br /> � �� � .��, j� ,�14 Municipal Offices <br /> ���`;l h'<�'!�''��'��yG Street Addmss: Ma11in�Addrou: <br /> '�EggO�' 2150 Kelley Parkway P.O. Box 66 <br /> Orano, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: Address: 1709 North Farm Rd. <br /> Permit #'s: 6336, 4029 Dates: 6/10/81, 10/21/91 Contractors: Widmer Bros. , Quickxay Exc. <br /> (This is [x] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The ssturated soil level ie [X] or is not [ ] identified undar this aeptic system. If the <br /> saturated soil level is not ideYit�fied, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> p� Pumpout not needed at this time. <br /> (6f Solids accumulation in tanks indicates they should be pumped out this year. <br /> �'1 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [�] or are not [ 7 �rater tiqht or the condition is [ ] unknown. If the tanka <br /> are not confirmed to be xatertight, thia classification ia subject to revision.) <br /> D INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: <br /> ����� <br /> Date of Inspection S tic Syste In pector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />