Laserfiche WebLink
� ��' . <br /> O :,#, O <br /> �,� ��; -� CITY of ORONO <br /> r�- �, <br /> � � <br /> �,� �S�,�:�'�� � ,�ti Nt��i�t o��� <br /> _ l ! ��7���'��'�"�G Street Address. Mailing Addross. <br /> ,9 �� r,,��`;;� ,g, <br /> $EggO 2750 Kelley Pa�kway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � <br /> Owner: IC�Y � Address: 1699 North Farm Rd. ' <br /> Permzt #'s: 5747 Dates: 10/3/79 Contractors: Sullivan <br /> (This is [�] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [�] or is not [ ] identified under this septic syatem. If the <br /> saturated soil level is not identified, this clasaification is subject to reviaion.) <br /> ,�'�K CONDITION (5-9) : 5 <br /> / 5/ Pumpout not needed at this time. <br /> �6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanka are [ ] or are not [ ] �vater tight or the condition is [�] unknomn. If the tanks <br /> are not confirmed to be vPatertight, this classification ie subject to re�iaion.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc.) : medium <br /> COI�IENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to <br /> public health or safety (surface discharqe or backup into the dwelling) . The system must be <br /> repaired or replaced by 12/31/2003 or within ninety days of posing an imminent threat to public <br /> health or safety, whichever comes first. <br /> ���� <br /> Date of Inspection Sep System I spector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />