<br /> Ground Source System 1 Performance Bin Data
<br /> Envision ND Dual Capacity Series 11 Tons with Horizontal Bore-0.75"PE
<br /> Heating Load is 117289 Btuh @ 68°F delta T / Cooling Load is 68370 Btuh @ 17°F delta T
<br /> Weather Loads WaterFumace System Aux HW
<br /> OAT°F Yrly Hrs Space HW Btuh/ Avg Loop Geo Air Geo HW Geo Geo Total Aux HW
<br /> Btuh/hr hr Temp Btuh/hr Btuh/hr Run kWh Gas ccf Gas ccf
<br /> Time
<br /> 97 2 82,736 2,521 69 108,527 3,306 76% 9 0 0
<br /> 92 33 68,370 2,521 64 109,901 4,052 62% 122 0 0
<br /> 87 128 54,004 2,521 58 111,251 5,193 49% 352 0 0
<br /> 82 268 39,638 2,521 53 112,528 5,379 35% 511 0 3
<br /> 77 432 25,272 2,521 48 113,754 3,983 22% 496 0 12
<br /> 72 620 0 2,521 47 0 0 0% 0 0 27
<br /> 67 713 0 2,521 47 0 0 0% 0 0 31
<br /> 62 735 0 2,521 47 0 0 0% 0 0 32
<br /> 57 609 -2,897 2,521 51 84,724 13,870 3% 170 0 22
<br /> 52 522 -11,521 2,521 49 82,619 13,608 14% 581 0 7
<br /> 47 468 -20,145 2,521 47 83,595 10,460 24% 883 0 0
<br /> 42 504 -28,770 2,521 45 84,621 7,414 34% 1318 0 0
<br /> 37 623 -37,394 2,521 43 84,337 5,685 44% 2085 0 0
<br /> 32 666 -46,018 2,521 41 83,443 4,571 55% 2721 0 0
<br /> 27 598 -54,642 2,521 39 82,220 3,793 66% 2888 0 0
<br /> 22 526 �3,266 2,521 38 80,799 3,219 78% 2934 0 0
<br /> 17 357 -71,891 2,521 36 79,251 2,779 91% 2261 0 0
<br /> 12 288 -80,515 2,521 34 80,515 2,521 100% 2050 0 0
<br /> 7 219 -89,139 2,521 32 89,139 2,521 100% 1746 0 0
<br /> 2 177 -97,763 2,521 30 97,763 2,521 100% 1564 0 0
<br /> -3 124 -106,387 2,521 30 100,612 2,521 100% 1131 9 0
<br /> $ 72 -115,012 2,521 30 100,612 2,521 100% 657 12 0
<br /> -13 46 -123,636 2,521 30 100,612 2,521 100% 420 12 0
<br /> -18 50 -132,260 2,521 30 100,612 2,521 100% 456 18 0
<br /> -23 8 -140,884 2,521 30 100,612 2,521 100% 73 4 0
<br /> -28 3 -149,508 2,521 30 100,612 2,521 100% 27 2 0
<br /> 8791 25456 58 133
<br /> This sofiware uses algorithms based upon the latest ASHRAE engineeing methods,20-year
<br /> average weather data,and a system installed according to the manufacturers guidlines.
<br /> However,due to the variability of weather,system installation,and living habits,this analysis
<br /> is to be considered an estimate. All analysis is based on WaterFumace unit performance
<br /> and may not be comparable for other manufacturers equipment.