2013-00541 - new structure
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Lane
>
360 North Arm Lane - 06-117-23-24-0012
>
Permits/Inspections
>
2013-00541 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:47 PM
Creation date
9/27/2017 1:53:54 PM
Metadata
Fields
Template:
x Address Old
House Number
360
Street Name
North Arm
Street Type
Lane
Address
360 North Arm La
Document Type
Permits/Inspections
PIN
0611723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A qualified geotechnical engineer shall confirm the assumed allowable soil bearing pressure in a <br /> geotechnical report, and the site shall be prepared in accordance. Any discrepancies in the assumed <br /> allowable soil bearing pressure shall be reported immediately. <br /> Remove all top soil, uncompacted fill, or other poor soil from the construction area. <br /> Slope the site to drain away from the building. <br /> Install gutters and downspouts with long extensions. <br /> Install drain tile. <br /> Backfill with granular soils. <br /> FOOTINGS/FOUNDATIONS <br /> All footings are to be formed. All stumps, roots and debris must be removed from the soil to a depth of at <br /> least 12" below the surface of the ground in the area occupied by the building. Footings shall be placed <br /> on virgin soil or compacted granular fill. <br /> Wall footings are cast-in-place concrete with continuous reinforcing placed 3"clear of bottom and 2"clear <br /> at top and sides. <br /> Wall footings are centered under walls and column footings under columns. <br /> Wall footings shall be a minimum of 10" thick with a 4" projection each side of wall. Reinforce with 2 -#4 <br /> continuous bottom bars. <br /> Column footings shall be a minimum of 12" thick, with plan dimensions as shown on drawing. Reinforce <br /> with#4 bottom bars at 8"o.c. each way. <br /> Provide 30 bar diameter lap at splices and full crossing lap at corners and intersections. Tie all reinforcing <br /> in place. Set footing reinforcing on chairs or masonry brick to obtain 3"clearance from bottom of footing. <br /> Maintain minimum frost depth of 42"for all exterior footings. <br /> Top of footing shall be placed 8" below the top of slabs on grade, or placed to maintain frost depth, <br /> whichever is deeper. <br /> Step footings in a uniform manner using a 2:1 horizontal to vertical slope. <br /> Cast dowels in footing for foundation walls above. Dowels shall be the same quantity, size, and spacing <br /> as the vertical wall reinforcing. Dowels shall be 30" long and extend to 3"clear of bottom of footing. <br /> Contractor shall be responsible for implementing hot weather concrete requirements per ACI 305 and <br /> cold weather concrete requirements per ACI 306. <br /> Shore all foundation walls appropriately before backfilling and compacting. <br /> Where foundation walls support unbalanced load on opposite sides of the building, such as a daylight <br /> basement, the rim board shall be attached to the sill with a 20 gage metal angle clip at 24" o.c., with five <br /> 8d nails per leg, or a connector supplying 230 pounds per lineal foot capacity. <br /> Foundations supporting wood shall extend at least 6"above the adjacent finished grade. <br /> At foundation endwalls, provide perpendicular full-height blocking at 24"o.c. in the first three joist spaces. <br /> Glue and nail to joists and subfloor. Attach to sill plate with 2- USP MP5 clips or equal. <br /> The contractor shall verify the location of all existing underground utilities and tanks prior to beginning <br /> excavation. <br /> The contractor shall follow Figure R403.1.7.1 for foundation clearances to slopes unless indicated <br /> otherwise by the soils engineer. <br /> CONCRETE <br /> Provide ready-mixed concrete per ASTM C94. Portland cement shall be ASTM C150, Type I. Use only <br /> one brand of cement throughout the work. Provide concrete aggregates meeting the requirements of <br /> ASTM C33. <br /> Maximum aggregate size shall be 3/4"for grade beams and slabs. Water shall be clean, free of <br /> deleterious amounts of acids, alkalis, or organic materials, and shall be considered potable. Provide <br /> admixtures to reduce water content, provide air-entrainment, or alter the quality of the concrete to meet <br /> the job conditions. <br /> Reinforce poured concrete walls with#4 at 12"o.c. horizontally and#4 at 12"o.c. vertically each face <br /> unless noted. <br /> Place reinforcing 2"clear to outside face and 1"clear to inside face of concrete wall. <br /> Provide#4 x 4'-0"long(equal legs) horizontal reinforcing corner bars at 12"o.c. at outside corner of wall <br />