My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-01147 - septic
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Lane
>
360 North Arm Lane - 06-117-23-24-0012
>
Septic
>
2011-01147 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:46 PM
Creation date
9/27/2017 1:53:23 PM
Metadata
Fields
Template:
x Address Old
House Number
360
Street Name
North Arm
Street Type
Lane
Address
360 North Arm La
Document Type
Septic
PIN
0611723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , <br /> � OSTP Design Summary Worksheet � jjgvIVERSITY ,� <br /> Minnesota Poltution t�.3.� �.;,, <br /> ControlAc�ency OF�INNESOT.� :r,,`��,. <br /> Property Owner/Ctient: Tony Lurtb <br /> Site Address: 360 North Arm road <br /> 1. AVERAGE DESIGN FLOW: <br /> A. Design F(ow: 6�0 Gdllons Per Day(GPD) Note: The estimated design flow is coraidered a peak flow rote including a sajety <br /> fcctor.For long term perjomance,the awervge dctly jlow is reoommernied to be< <br /> B. Septfc Tonk capacity: 2250 Galtons 6o%of this volue. <br /> �. Number of SepNc Tanks or Compartments: � Effluent Screen&Alarm? Y@S <br /> Type af So�Treatrnait and 0�1 Aree" TypE of D�on# <br /> O r�a,es O eee O a�a O ac-c,r�ae O c,rav�ry o�,r;on OO rre�.e o�,doo-� O rre�,re�-u�� <br /> O or�D� O wo�-Haa�Ta�s o�y <br /> 'Selection Required Benchmark Elev= 100 ft <br /> System Type Benchmark Location: Top Wet) <br /> Q Type I �Type II ❑Type II I ❑Type IV ❑Type V Type of Distribution Media: <br /> Rock <br /> 2. SITE EVALUATION: <br /> A. Depth to Limfting Layer: 19 inches 1.6 ft Elevation of Limiting Layer: 96.1 <br /> B. Mecsured Percent lond Slope: 8.0 % 0.0 <br /> C. Soil Texture: Loa�1 Percolation Rate: �Minutes per Inch <br /> D. So9l Hydraulic Loading Rate: 0.60 GPD/ft2 E.Contour Loading Rate 12.0 Gal/ft <br /> 3. DESIGN SUMMARY <br /> Trench Design Summary <br /> Absorption Area �ftz Sidewalt Depth �in Trench Width �i� <br /> Total Lineal Feet ��ft Number of Trenches � Maximum Trench Depth �in <br /> Designer's Max Trench Depth in <br /> Bed Design Summary <br /> Absorption Area �ftz Media Below Pipe �in Bed Length �ft <br /> Bed Width �ft Maxfmum Bed Depth �in Desfgner's Max Bed Depth �in <br /> Mound Design Sutnmary <br /> Absorption Area [�}� Bed Length �ft Bed Width ` Q ft <br /> Absorption Width „(� ft Clean Sand Lift �ft geRn Width (slope 0-1%) �ft <br /> Upalope Bertn Width �� R Downabpe Berm Width � „ ' R Endsiope Bertn Width f.�ft <br /> Total System Length �ft Totat System Width �ft , <br /> /At-farad�Dosign Summary <br /> Absorption Bed Width �ft Absorption Bed Length �ft System Height �ft <br /> Absorption Bed Area �f�z Upslope Bertn Width �ft Downslope Bertn Width �ft <br /> Endsbpe Berm Width �ft System Length �ft System Width �ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.