MORTON BUILDINGS GENERAL SPECIFICATIONS <br />LAMINATED COLUMNS — NO. 1 OR BETTER SOUTHERN YELLOW PINE NAIL LAMINATED 3 MEMBER S4S <br />COLUMNS USED IN MORTON BUILDINGS ARE PRESSURE TREATED BELOW GRADE TO A RETENTION OF .8 <br />POUNDS PER CUBIC FOOT WITH CHROMATED COPPER ARSENATE TYPE III, OXIDE. TYPE, AS LISTED IN <br />FEDERAL SPECIFICATION TT—W---571J, THE TREATED PORTION OF THE COLUMN EMBEDDED IN GROUND <br />SHALL BE LAMINATED WITH STAINLESS STEEL NAILS, <br />FOOTINGS AND ANCHORAGE -- COLUMN HOLES ARE DUG 4 FEET DEEP MIN, DEPTH BELOW GRADE AND <br />READY—MIX CONCRETE PADS OR DRY CONCRETE MIX PADS ARE POURED IN PLACE (NOTE PLANS FOR <br />SIZE & TYPE), TWO GALVANIZED STEEL BASE ANCHORS ARE PLACED 1" FROM BOTTOM OF COLUMN <br />OR 1/2" GALVANIZED STEEL ROD PLACED 2 1/2" FROM BOTTOM OF COLUMN,( SEE SECTION )ADDITIONAL CONCRETE <br />IS MIX POURED AROUND BASE OF COLUMN THEN BACKFILLED WITH SOIL AND COMPACTED AT 8" INTERVALS. <br />SPLASHBOARDS — SPLASHBOARDS ARE NO. 2 OR BETTER SOUTHERN YELLOW PINE 2"x8" S2S AND CENTER <br />MATCHED, PRESSURE TREATED TO NET RETENTION OF ,6 POUNDS PER CUBIC FOOT WITH CHROMATED COPPER <br />ARSENATE TYPE III, OXIDE TYPE, IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS' ASSOCIATION SPECIFICATION <br />C2. ONE ROW IS FURNISHED FOR BUILDING ON A LEVEL SITE, <br />FRAMING LUMBER —SIDE NAILERS ARE 2"x4" S4S OR 2"x6" SPF NO.2 OR BETTER SPACED ApPRcwMAT l,Y 30" O.C. <br />WITH ALL JOINTS STAGGERED AT ATTACHMENT TO COLUMNS, ROOF PURLINS ARE' 2"x4" S4S NO. 2 OR <br />BETTER ON EDGE SPACED APPROXIMATELY 24" O.C, ALL OTHER FRAMING LUMBER IS NO. 2 OR BETTER. ( SEE SECTION ) <br />ROOF TRUSSES — FACTORY ASSEMBLED WITH 18 OR 20 GAUGE GALVANIZED STEEL TRUSS PLATES AS <br />REQUIRED AND KILN DRIED LUMBER AS SPECIFIED, IN --PLANT QUALITY CONTROL INSPECTION IS CONDUCTED <br />UNDER THE .AUSPICES OF THE TPI INSPECTION BUREAU. TRUSSES ARE DESIGNED IN ACCORDANCE WITH . <br />CURRENT STANDARDS AND SPECIFICATIONS FOR THE STATED LOADING. <br />SIDING PANELS (KYNAR 500/HYLAR 5000 —0-019" MIN., G90 GALVANIZED OR AZ55 <br />GALVALUME, WITH AN ADDITIONAL BAKED—ON KYNAR 500/HYLAR 5000 FINISH, PAINT IS <br />NOM, 1 MIL THICK ON EXTERIOR <br />ROOFING ""NEL S (KYNA.R 5007HIY R 5000) —0.019" MIN., G90 GALVANIZED OR AZ55 <br />GALVALUME, WITH AN ADDITIONAL BAKED—ON KYNAR 500/HYLAR 5000 FINISH, PAINT IS <br />NOM, 1 MIL THICK ON EXTERIOR, <br />TRIM —DIE—FORMED TRIM OF 0,019" MIN,, G90 GALVANIZED OR AZ55 GALVALUME STEEL <br />ON GABLES, RIDGES, CORNERS, "BASE, WINDOWS, AND DOORS WITH SAME FINISH AS <br />ROOFING OR SIDING PANELS . <br />GUTTERS — 5" K—STYLE, .030 HIGH TENSILE ALUMINUM GUTTER, KYNAR 500/HYLAR 5000 <br />FINISH TO MATCH TRIM, ON BOTH SIDES OF THE BUILDING. <br />ADDITIONAL NOTES <br />1,) ALL PLOT ,PLANS AND RELATED DETAILS SHALL BE PROVIDED BY ll"vYNER UNLESS. I_"•COILIPOReTEn AS PART <br />OF THESE DRAWINGS, <br />2.) ALL INTERIOR PARTITIONS AND ROOM FINISHES IF NOT INCLUDED WITH THESE DRAWINGS SHALL BE PROVIDED <br />BY OWNER, STANDARD FINISHES SHALL HAVE LESS THAN 200 FLAME SPREAD RATING AS REQUIRED BY <br />ASTM E84 FOR ORDINARY CONDITIONS AND 25 OR LESS FOR EXITS, PASSAGEWAYS, AND CORRIDORS. <br />3.) FLOOR COVERINGS JUDGED TO REPRESENT AN UNUSUAL HAZARD SHALL MEET THE SAME TESTING PROCEDURES <br />AS REQUIRED FOR WALL AND CEILING FINISHES, <br />4,) MORTON BUILDINGS GENERAL SPECIFICATIONS APPLY UNLESS INDICATED DIFFERENTLY ON SPECIFIC <br />JOS DRAWINGS OR SUPPLEMENTAL INFORMATION. <br />5.) KYNAR 500 IS A REGISTERED TRADEMARK OF ELF ATOCHEM NORTH AMERICA, HYLAR <br />5000 IS A TRADEMARK OF AUSIMONT, USA, <br />CS2x4KK 2-96 <br />t ul!_DING DESN C R 1 T E R 1A I <br />USE GROUT _ U1 <br />CONSTRUCTIDN TYPE <br />VN <br />LIVE ROOF LOAD DESIGN <br />40 PSF <br />WIND LOAD 80 <br />MPH EXP. C <br />FLOOR AREA <br />1200 SQFT <br />.. ,..tai <br />OI I Or ORONO <br />BUILDING PERMI PLAN REVIEW <br />INSPECTOR - <br />DATE _ PERMIT NO.____ <br />IK A^; ROVED AS SUB.""ITTED <br /><k' PROVE'D4 4 I T H COR; IE^TiONIS AS ?NOTED <br />EI "ifl t-.-7 <br />ter A"FRO..; �j --- Y ClRF,, <br />.7'. , RES• f;: 4IT <br />The_ ­o comments are I+;,c, so;ii $ iut <br />r },GUY !n-nn;c t, X! ': { b"3 dow <br />in i <br />• ,y `r ! COIMPl+eh aN apofic`tbie hlit-li g and zerrm, cQc: & <br />SL,quirements iindur;in., '.ems no; �aci€:avi .;_ din tF, Er • s�4. <br />KEEP THIS PLAN SET ON 64TF.,AT ALLT <br />i TICAL <br />LUtvitSE i S 'ECIFICATIONS — <br />SHEET <br />H <br />INDEX <br />SHEET <br /># <br />DESCRIPTION <br />1 OF <br />4 <br />SPECIFICATIONS & SHEET INDEX <br />2 OF <br />4 <br />COLUMN PLAN & ELEVATIONS <br />3 OF <br />4 <br />SECTIONS & DETAIL <br />4 OF <br />4 <br />1 TRUSS DRAWING <br />.. ,..tai <br />OI I Or ORONO <br />BUILDING PERMI PLAN REVIEW <br />INSPECTOR - <br />DATE _ PERMIT NO.____ <br />IK A^; ROVED AS SUB.""ITTED <br /><k' PROVE'D4 4 I T H COR; IE^TiONIS AS ?NOTED <br />EI "ifl t-.-7 <br />ter A"FRO..; �j --- Y ClRF,, <br />.7'. , RES• f;: 4IT <br />The_ ­o comments are I+;,c, so;ii $ iut <br />r },GUY !n-nn;c t, X! ': { b"3 dow <br />in i <br />• ,y `r ! COIMPl+eh aN apofic`tbie hlit-li g and zerrm, cQc: & <br />SL,quirements iindur;in., '.ems no; �aci€:avi .;_ din tF, Er • s�4. <br />KEEP THIS PLAN SET ON 64TF.,AT ALLT <br />i TICAL <br />LUtvitSE i S 'ECIFICATIONS — <br />1997 <br />NDS <br />SIZE <br />DESCRIPTION BENDING VALUE Fb <br />2"x4" <br />N0.1&2 SPF <br />1313 <br />PSI <br />2"x4" <br />2100f MSR SPF <br />2100 <br />PSI <br />2"x6" <br />NO.1 &2 SPF <br />1138 <br />PSI <br />2"x6" <br />NO. 1 SYP <br />1650 <br />PSI <br />2'x8 <br />NO. 1 SYP <br />1500 <br />PSI <br />2%1 Off— <br />NO. 1 SYP <br />1300 <br />PSI <br />2'x12" <br />N0, 1 SYP <br />1250 <br />PSI <br />ALL <br />1950f NISR SYP <br />1950 <br />PSI <br />1 1/2"x`16" <br />LAMINATED VENEER LUMBER <br />2800 <br />PSI <br />3 1 2 x15 <br />CLU—LAM <br />1650 <br />PSI <br />51 4"x16 1 2 <br />GLU--LAM <br />2400 <br />PSI <br />51 4'x19 1/2* <br />GLU--LAM <br />2400 <br />PSI <br />NOTE: HIGHER GRADE MATERIAL REQUIRED AS NOTED ON PLANS, <br />I HEREBY CERTIFY THAT THE STRUCTURAL DESIGN FOR <br />THIS BUILDING WAS PREPARED BY ME OR UNDER MY <br />DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED <br />PROFESSIONAL ENGINEER. <br />0 ALD L. SUTTON, P.E. 9 <br />MICHAEL L. McCORMICK P.E. _ <br />DATE: - 4 --& REG, # Z-- t� <br />OFFICE: <br />MONTICELLO, MN <br />JOB N0. <br />59-0211 <br />z <br />0 <br />z <br />0 <br />.0 <br />U <br />Z <br />DRAWN <br />BY: <br />844 RYAN <br />DATE: <br />3/14/00 <br />CHECKED BY: <br />GMC <br />DATE: <br />04/06/00 <br />REVISED <br />DATE: <br />REVISED <br />DATE: <br />REVISED <br />DATE: <br />REVISED <br />DATE: <br />SCALE: <br />SHEET NO. <br />1 of 4 <br />