1995-006980 - new septic system
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Dr W
>
4590 North Arm Drive West - 06-117-23-24-0016
>
Septic
>
1995-006980 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:59 PM
Creation date
9/21/2017 1:50:31 PM
Metadata
Fields
Template:
x Address Old
House Number
4590
Street Name
North Arm
Street Type
Drive
Street Direction
West
Address
4590 North Arm Dr W
Document Type
Septic
PIN
0611723240016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S'P �'ESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 <br /> April 18 , 1995 <br /> Barry Hoglund <br /> 4590 Nort':Z �.rrl i)ri�,-=� <br /> Orono, Henn. Co . , MN <br /> This On-Site Sewage Treatment System is Designed for a Type l, four <br /> bedroom home Designed in accordance with the Minnesota Pol,lution <br /> Control Agency ^hapter 7080 and local ordinances . <br /> The soils or� this si�te are a clay loam. A seasonally saturated <br /> layer of soil was found at 20" to 26" , (mottled soil ) . Due to <br /> the seasonally saturated soil , a Pressurized Mound System will <br /> need to be installed to adequately treat septic effluent. <br /> This site has an existing non-conforming system due to not meeting <br /> the 3 ' seperation from the seasonally saturated soil . Tne �xisting <br /> tanks may be used upon approval by the local Inspector. The tanks <br /> must be water tight . If the tar�ks need to be replaced , recommend <br /> to relocate ther� apprax. 40 ' east of their present location. <br /> The soils at a depth of 12" have a percolation rate averaging <br /> 4 . 2 min/inch. <br /> A pumping chamber will need to be installed to lift the effluent <br /> to the treatment area . <br /> The manifold and supply line pipe must have back drainage to the <br /> pumping chamber. The distribution pipes shall have their ends <br /> capped. Be sure the rock and sand fill material are clean. The <br /> sod layer below the entire mounded area must be turned over, just <br /> break up the sod, be sure not to over work. <br /> The power supply and switches must be located outside the manhole <br /> and pumping chamber in a weather proof enclosure. A warning device <br /> must be installed ��ith a light and sound device, this is in case of <br /> a pump failure. <br /> All neighboring wells are located greater t!�an 100 ' away from the <br /> proposed treatment area . <br /> CONT ' D <br />