<br /> - �I��RHVAC=Residential&Ltght Commercial HVAC Loads Program � Elite Software Development,Inc. �
<br /> '�itter,inc. RICHARDSON
<br /> i Hamel,MN 55340-9691 10-12-2001 Page 2 i
<br /> i -- -----------------__--_ _--_
<br /> - - - --- - --
<br /> ____ __-._ __ __ __ .. _
<br /> System#1 Summary Loads
<br /> ' -- - ',
<br /> --- -- -------- _. -- ___ _-- - -- -
<br /> � Component Area Sen. Lat. Sen. Total ',
<br /> Description Quan Loss Gain Gain Gain
<br /> - ---------- - ---------- --- '
<br /> � 3A Window Double Pane Clear Glass Wood Frame 220 11,152 0 11,312 11,312 '
<br /> 10F Door Wood Solid Core& Metal Storm 63 1,854 0 477 477 ;
<br /> 12C Wall R-11 + 1/2"Gypsum(R-0.5) 1,621 13,422 0 3,443 3,443 �
<br /> 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 896 6,594 0 1,690 1,690
<br /> 16G Ceiling R-30 Insulation 768 2,332 0 1,115 1,115
<br /> 21A Basemt Floor 2'or More Below Grade 768 1,696 0 0 0 !,
<br /> Subtotals for structure: 4,336 37,050 0 18,037 18,037 �
<br /> i Active People: 6 0 1,380 1,800 3,180 ;
<br /> Inactive People: 0 0 0 0 0 �
<br /> Appliances: 0 0 0 1,200 1,200 �
<br /> Lighting: 0 0 0 ��
<br /> Ductwork: 0 0 0 0 0 I
<br /> Infiltration: Winter CFM: 184.3, Summer CFM: 92.2 283 18,098 2,188 1,967 4,155 '
<br /> Ventilation: Winter CFM: 25.0, Summer CFM: 25.0 0 2,455 594 534 1,127 ��
<br /> --- ---- ----------------- --- ;
<br /> Sensible Gain Total: 23,538 ;
<br /> Temperature Swing Multiplier: X1.00
<br /> -- --- - -- - �
<br /> - - ------ -
<br /> i System Load Totals: 57,603 4,162 23,538 27,699 '
<br /> I -- ------------- --_ ----___ - _ _ __ _ -- _
<br /> Check Figures I
<br /> - - -------
<br /> Supply CFM: 1,078 CFM per square foot: 1.403 �i
<br /> Square feet of room area: 768 Square feet per ton: 293.657 ,
<br /> i
<br /> System Loads - - ------ ------ --- --
<br /> Total heating required with outside air: 57,603 Btuh 57.603 MBH
<br /> Total sensible gain: 23,538 Btuh 85 % i
<br /> Total latent gain: 4,162 Btuh 15 % I
<br /> Total cooling required with outside air. 27,699 Btuh 2.308 Tons (based on sensible+ latent) �i
<br /> 2.615 Tons(based on 75% sensible capacity) '
<br /> I Notes
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary. ,
<br /> Be sure to select a unit that meets both sensible and latent loads.