2017-00340 - septic
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
725 Lakeview Parkway - 06-117-23-34-0008
>
Septic
>
2017-00340 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:27 PM
Creation date
8/16/2017 9:58:54 AM
Metadata
Fields
Template:
x Address Old
House Number
725
Street Name
Lakeview
Street Type
Parkway
Address
725 Lakeview Pkwy
Document Type
Septic
PIN
0611723340008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purplecode Mound Design <br /> www SepticResource com (vers 15 2j <br /> Property Owner: Swanson Homes Date: 1,'9,'2017 <br /> Site Address: 725 Lakeview Parkway PID: 061 t72334Q008 <br /> Comments: <br /> instructions: � =enter data � = adjust if desired � = computer calculated - DO NOT CHANGE! <br /> ��bedroom Type �� Residentiat System <br /> _� 750 GPD design ftow <br /> Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br /> �� 2250 Gat Septic tank �code minimum) 2250 Gat Septic tank (design size J LUG req'd) <br /> Tank options: none <br /> 1•2 GPD/ft�mound sand toading rate contour toading rate of 12 req's a min 62.5 ft. long rockbed <br /> ��; 10.0 ft rockbed width 63.0 ft rockbed tength <br /> ,� 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both� <br /> end feed manifold connection <br /> �- ��laterals 61.0 feet lang 21.0 perfs J lateral 63 perfs total <br /> (1!2 a perf means the first perf starts at the middle feed manifold) <br /> u 7/32 inch perfs at �feet residual head gives 0.56 gpm ftow rake per perforation <br /> for ihis perf size &spacing, ft pipe size on tine 12, max perfs/tateral = 30 , line #8 must be less --> px <br /> �+�� 4.0 doses per day ( 4 minimuml <br /> i i� 188 gallons per dose jtreatment votumei <br /> 2.OQ 5x <br /> i�; 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> i;, 142 feet of 2.0 inch supply line leads to 24 gallons of drainback votume <br /> iTip: "top feed" manifold [o controt the drainback� <br /> ��� 212 gatlons TOTAL pump out volume (treatment * drainback� <br /> �� 15 feet vertical lift from pump to mound taterats, leads to a: <br /> ��� 36 GPM� 26 feet of head, Pump requirement �note: >50gpm may require an extra 3-6'of head) <br /> i" 750 gat Dose tank (code minimum) 1300 gat Dose tank (design size / LUG req'd► at 24.49 gpi <br /> leads to a <br /> �: 8.7 inch swing on Demand float, or timed dosing of 5.9 min ON (confirm pump rate with drawdown <br /> (this detivers Average flow, =70�of Peak design ftow►�hrs OFF test and adjust as necessary) <br /> i�� 12 inches from bottom of tank to"Pump OFF"ftoat <br /> =��; 21 inches from bottom of tank to "Pump ON"float, or 12 inches to"Timer ON"ftoat if time dosed <br /> 'i 24 inches from bottom of tank to"Hi Level"float, or 34 inches to"Hi �evel"ftoat if time dosed <br /> __ 712 gallons reserve capacity (after High Level Alarm is activatedi <br />