2017-00340 - septic
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
725 Lakeview Parkway - 06-117-23-34-0008
>
Septic
>
2017-00340 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:27 PM
Creation date
8/16/2017 9:58:54 AM
Metadata
Fields
Template:
x Address Old
House Number
725
Street Name
Lakeview
Street Type
Parkway
Address
725 Lakeview Pkwy
Document Type
Septic
PIN
0611723340008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iNSPECTOR CHECKL.IST - mound <br /> /t5 LaKeview Narkway <br /> � WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 10�'to dispersal area with shaltow well <br /> PROPF.RTY LItiF:S setback: 10'to everything <br /> Road setback: platted: 10'prop tine. Metes fr baunds:out of road easement, or outer ditch. <br /> LAhE BI,[:f�I setback: 20'for bluff. Lakes: GD_, RD_, NE_. Protected wettand_. <br /> Building srtbacks: 10'for everything, 20'for dispersal area. <br /> �t"Al ER l.l'�F.under pressure se 10'to bed,tank Es sewer line. tetse sewer tine > 12"below) <br /> � Sewer line & baffle connettion (no 40's, 3'between 45's, slope min t" in 8', max 2"in 8') <br /> (no depth req's, ctean out every 100', Sch 40 pipe) <br /> � Septic tank and risers {water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gatlons none <br /> Riser over outtet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> No effluent filter&atarm <br /> Dose tank risers and piping (water tight, insutated, proper depth, drainback) <br /> mfg 1300 galtons <br /> � dose pump 36 gpm 26 head VERIFY PUMP CURVE 5.9 min ON 9 hr OFF <br /> � ftoat setting drop 8.7 inches at 24.5 gpi "Df51GNED" 5.4 inches approx float tether length <br /> 212.0 gai dose divided by gpi "INSTALLED"= inches float drop (fietd corrected <br /> LABEI pump requirements and drawdown on riser or panet <br /> Cam lock reachabte from grade - 30" max. J-hook weep hole. Suppty tine access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> sptice box / controt panet / electricat connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorptio�area rough up <br /> mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 20 inches. (Jar test : 2"sand teaves � 1/8"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upstope 10.0 downslo� <br /> � Bermed topsoil beyond rockbed 11 upstope 13 sidestope 22 downstope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rock� <br /> 2.00 inch pipe size (Sch40 pipe& fittings) <br /> 3.0 ft lateral spacing <br /> 8 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifotd if necessary. VERIFY <br /> clean outs �no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary C�Re-use existing tank certification <br /> monitoring ptan and type <br /> welt abandonment fo�m - if necessary <br />