Laserfiche WebLink
--- <br /> _� <br /> %�O �;,�. <br /> / �' �' �� <br /> ;�;� O O ����� <br /> � � � ��'�� CITY of ORONO <br /> '������ ,� ���a���l,�,�, �� ,� �� <br /> � �', , 'i,•:� �l4 jj' Municipal Offices <br /> � ' �� , ��. <br /> � � �.�G�� Street Address: Mailing Addross: <br /> �� �CEggO ,� 2750 Kelley Parkway P.O. Box 66 <br /> = Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: '� �s Address:70 Myrtlewood Rd. <br /> Permit #'s:none Dates: Contractors:unknown <br /> (This is � an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant Svstem: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> � with previous codes and is functioning properly. <br /> j 3J Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> �� construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level . <br /> (The saturated soil level [�] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision. ) <br /> TANK CONDITION (5-9) : 6 <br /> 5_ Pumpout not needed at this time <br /> � Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not <br /> been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [� ] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the a ks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION 11-14 : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> ' 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system acie and condition, soils, etc. ) : high <br /> COMMENTS: The non-conforminq septic system must be repaired bv 12/31/2006 . <br /> ���� � �„ _.., <br /> Date of Inspection S ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telep6one (612) 4�3-7357 • FAX 473-0510 <br />