<br /> To Current Owner:
<br /> Address: �� �'� ��''�t�^^tld{�
<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> S STEM CONFORMITY 1-3 : �
<br /> 1 "CODE SYSTEM" An ISTS which mcets all the location,design and construction standards of the current Orono Municipal Code.
<br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
<br /> Municipal Code but does moet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
<br /> which is aot failing or an imminent threat to public health or safety.
<br /> 3 "NON-COMPLIAN'I'SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
<br /> or may not meet all the location,design,or construction scandards of thc current Orono Municip�l Code and which is failing for any -
<br /> reason;and any ISTS with less than thra feet of unsahirated soil or sand between the distribution device and the limiting soil characteristics.
<br /> TANK CONDITION(5-7): �
<br /> �T nk inspection indicates:
<br /> Pumpout not needed at this time.
<br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
<br /> Tank was last pumped 1 L C d2— )•
<br /> Make sure seatic tanks are pumaed throueh manhole and not through white insaection aiaes. This a__I_lows for the aroaer
<br /> cleaning Keep water softner and iron filter discharae out of septic svstem to prolong life of dra�nfield. Ask aumoer to test
<br /> alarm float to verifv alarm is still workins in vour house The alarm warns owner that seatase is about to backua mto basement.
<br /> 7 Inspection risers missing-tanks could not be inspected. Inspect�on risers(4"dia.pipe)must be installed m each tank. If
<br /> tanks have not been pumped out within the last three years,thay should be pumped out now.
<br /> D INFIELD CONDITION 8-10 : �
<br /> Drainfield is dry,no surfacing evident.
<br /> Some evidence of surfacing,not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be compteted within 90 days.
<br /> _> C4MMENTS: I�"�
<br /> ��.� �}--. ` �t�}�,� ..-�.�ICS . . I a�C. �l�
<br /> __----- . .
<br /> ��'��-�.� ` �'''"s
<br /> �, �Da�e of.�nsp�ction; � Matt Bolterman - Septic System Inspectar
<br /> � � � . ° � � z. � , � �� � , . :,
<br /> �.., � y ( n: `J'... �k, };. s�, , ,. , :
<br /> , � Nc�t�: Ln die.�'ven�thaC'�iis t�aspccCion t�por��s u5�d to Satisfy�the�requ�reme3tts fiYs a �artgage ar oCher trahsfer of praperty,be advi�ed that k�is report does.
<br /> � '�:not guaaYtnt�;or `� ify`thaC^8n e�istir�sy�kem �rkll �antin�ke to �unctt`�n pcoperLy but'ts•tnerely an opinion Gf tGe adequaeY of E�e system undtr cureent
<br /> �`' � ,r � M., � ,. � �„ + � �
<br /> 3:.. �,� 1�
<br /> �,_. � .��;��1ati�b°��.',d �thC,�atl�le i4��°�� -,.�;: �� ,��"'": � �' � .� ,� +� ,� � „ � n, . a . ` � ^ h �
<br /> � C� .: � ��". °� �?« �Yy,� .� . ...`�. l�x- . . u#8.�$. ��4?2.'J:�.. ..
<br />
|