Laserfiche WebLink
� O� _ <br /> O : O <br /> ���� �-�- CITY of ORONO <br /> ;,..- <br /> � � ,-_ <br /> a �.���:��� _ � <br /> ,�, � n: �:, . �ti M�;��� otr,�� <br /> \ �1 t,'�� �.Lr �� <br /> \�� ��,��`�. �;, ,�G Street Address: qsa-�49-y6o O Malling Addross: <br /> 9$EgHO�' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: J� ��f r�")�-�DDv �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> The on-site sewage treahnent system at the above address has been inspected and appeazs to fall into the categories checked below. <br /> S� S"TEM CONFORMITY 1-3 : I <br /> 1 `CODE SYSTEM"?,n�ISTS which meets all the loca6on,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An IST'S which does not meet all the location,design and consiruction standards of the current Orono <br /> Municipal Code but dces meet the three foot separation requirement or two foot requir�ent for systems installed 1996 or earlier,and <br /> which is not ffiiling or an ia�►inent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and wlrich is failing for any <br /> reason;and any ISTS with less than three feet of unsadirated soil or sand between the distribution device and ttie limiting soil characteristics. <br /> TANK CONDITTON(5-71: S <br /> Tank inspection indicates: <br /> 5�1'umpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �0-1`6'U`f ). <br /> Make sure seatic tanks are aumced throueh man6ole and not through white iasaection uiaes. This allows for the proner <br /> cleaninQ. Keeu water softner and iron filter discharee out of seatic svstem to arolone 6fe of drainfield. Ask oumner to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner t6at se�ta¢e is about to backuu into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Insp�tion risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> IELD CONDI'TION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield.is saturated and visibly discharging�r►treated ef�luent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMN�NTS: _ M t•• �, �" ScQ�;L �-��lf,� �oh� b� . <br /> �-��—o� G1� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or otha transfer of property,be advised that this report dces <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />