My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
M
>
Myrtlewood Road
>
15 Myrtlewood Road - 36-118-23-33-0013
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:03:14 PM
Creation date
8/1/2017 12:15:30 PM
Metadata
Fields
Template:
x Address Old
House Number
15
Street Name
Myrtlewood
Street Type
Road
Address
15 Myrtlewood Road
Document Type
Septic
PIN
3611823330013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� .�O <br /> CITY OF ORONO � <br /> M�icipal Offices O � O <br /> Post Office Box 66 . <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(iE TREATN�NT <br /> � ti INSPECTION REPORT <br /> '�� G~ <br /> 9kEsxo�'� <br /> Owner• Address• <br /> Permit #'s:�Y�Y1P. Dates: � Contractors: //Yl K�Y1�IwN\ <br /> City ordinance number 100 requires that each on-site sewage treatment _system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has .been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> "CONFORMING STSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactority by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into gro�d or surface waters. <br /> 3 "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or send <br /> between the distribution cJevice and the limiting soil charecteristics. <br /> (The timitin� soil characteristic [ l has or ,[7S.has not been identified at this time. tf the limiting soil <br /> characteristic has not been identified, this cYassification may be subject to revision.> <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> � Punpout not needed at this time. <br /> Solids accunulation in tanks indicates the should r to hel r future roblems. <br /> Solids accumulation in tanks is at a cri ice eve an s s ou out as soon as pos <br /> 8 System is discharging to the surface. Tanks must be puniped out within 48 hours to eliminate surface�discharye. <br /> 9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be instelled in each <br /> tank at next punpout. If tanks have not been pu�ed out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directl over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been pu�out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDiTION C11-14): <br /> Dy�f�ifield inspection indicates: <br /> 111P Drainfield is dry, no surfacing evident. <br /> �47 Some evidence of surfacing, rwt critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Dreinfield extent and condition unkno►m. <br /> LIMITING SITE FACTORS (sloae,setbacks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table,etc.): � <br /> COMMENTS: <br /> Date of Inspection Septi ystem Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an op�m on of the adequacy of the system under current conditions based on the available <br /> informatton. <br /> This report must be kept on the premises with the system locetion and punping records. <br /> WHI7E COPYllnspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.