My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
M
>
Myrtlewood Road
>
10 Myrtlewood Road - 36-118-23-33-0009
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:03:05 PM
Creation date
8/1/2017 11:32:33 AM
Metadata
Fields
Template:
x Address Old
House Number
10
Street Name
Myrtlewood
Street Type
Road
Address
10 Myrtlewood Road
Document Type
Septic
PIN
3611823330009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Municipat Offices O O <br /> Post Offite Box 66 <br /> Crystal Bay, MN 55323-0066 a � ON—SITE SEWA(�E TRFATl�NT <br /> INSPECTION REPORT <br /> ti <br /> ti <br /> ��9k o4�G <br /> EsH <br /> Owner• l /i�I!1�.�� l/1/J��� Address• <br /> Permit �'s: Dates: >���' Contractors: • <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewege treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is �an existing system [ ] neW construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any poltutants into ground or surface waters. <br /> 2 "CONFORMING SVSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> � is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> ��NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplein; any <br /> system which may or mey not meet all the location, design, and construction standards of the current City <br /> Codes and whic� is failing for any reason; end any system with less than 3 feet of saturated so't or sand <br /> between t e �stri ion i.�.*art�the—timrting so�l characteristics. ���rw/,�<� ��� <br /> �I(ll <br /> (The limitin� soil characteristic [ l has or�has not been identified a this time. If the limit ng soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONOITION CS-10): � � � � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at is time. <br /> �b�, Solids accunulati n tanks indicates they should be o ' ture roblems. <br /> (� ' ' in tanks is at a critical l s ould be punped out as soon as pos <br /> '$ System is discharging to the surface. Tenks mu ' ' ' ' ar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next punpout. lf tanks have not been punped out within the last three years, they should be Fxmped <br /> out now. <br /> 10 tnspection pipe is loceted directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Drainfield inspection indicates: <br /> 11 Drainfie[d is dry, no surfacing evident. <br /> 1�Some evidence of surfacing, not critical yet. <br /> T�S � Drainfield is saturated and visibly discharging untreated effluent to the surface. Contect the City inspector <br /> immediately. Jtepeirs must be c�_t_ei� within 90 days. <br /> 14 Drainffi�dex�ent�a cor�i 'fi ion �m nown. <br /> LIMITING SITE FACTORS (sloae,setbacks,etc.): <br /> POTENTIAL FOR STSTEM FAILURE (deaends on soils,water table,etc.): <br /> COMMENTS: <br /> Date f Inspection Syste Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this rejwrt does not guarantee or certify that an existing system will continue to fimction <br /> properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system lxation and pumping records. <br /> WHITE COPY/Inspsctora File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.