Laserfiche WebLink
�°� <br /> ,, o 0 <br /> -- �� T CITY of ORONO <br /> ,� :t�� � <br /> � <br /> � � y� �l�r MunicipalOt'P�ces <br /> t �-. ¢ '� <br /> ,t ,+4':�'�?`-�°�G Street Addr�as: MalUna Addross: <br /> '�'�Kp�" 2150 Kelley Pa�kway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: Q U f 1�J 0 ` Address: 517 Ferndale Rd. N. <br /> Permit #'s: 6878 Dates: il/16/82 Contractors: Widmar Bros. <br /> (This is [� an existing system ( ] new construction) . <br /> SYSTEM COMPLIANCE (1-3} : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> O3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level is ( ] or is not [ ] ideatified uader this septic systaaa. If the <br /> saturatad soil lmvel is aot i eat fied, thia classification is subjact to ravisioa.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9� Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been um ed out within three years, the sho t now. <br /> 10 One or more tanks are cesspoo s, w ic means the septic system is non-comp iant. <br /> (The tanks are [ ] or are aot [ ] vrat.r tiQht or the coadition is [ � unknoma. If the tanks <br /> are aot coafirmed to be watartiQht, this classification is aubject t reviaioa.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : madiwn <br /> CONID�NTS: The septic system is non-compliant, but does not appear to pose an imminent threat to <br /> public health or safety (surface discharge or backup into the dwelling) . The system must be <br /> repaired or replaced by 12/31/2002 or within ninety days of posing an imminent threat to public <br /> health or safety, whichever comes first. <br /> /—�� <br /> Date �of Inspection Se ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Tdep6one (612) 473-'f357 • FAX 473-0510 <br />