Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC Loads � �, Elite Software Development,Inc. <br /> Sabre Plumbing&Heating � 669 Minnetonka Hiqhlands Rd.Long Lake <br /> Ptymouth,_MN_55447 __ ___ __ _ ____ _ Page 4_� <br /> Total Building Summary Loads_ __ _ <br /> IDe cp ptiont- -- _ -- - -- - _Quan _- oss - -Ga n Ga n Ga n�! �' <br /> i LOW EE: Glazing-Builder Grade Low E Windows& 207 5,769 0 6,108 6,108 <br /> Sliding Door.32 U value .30 SHGC, u-value 0.32, 'I <br /> SHGC 0.3 i <br /> 11J: Door-Metal - Fiberglass Core 80 4,176 0 1,152 1,152 , <br /> 15A-15sffc-8: Wall-Basement, concrete block wall, R-15 1168 3,456 0 0 0 I <br /> , foam board to floor, no framing, no interior finish, <br /> i filled core, 8'floor depth , <br /> ' R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 6017 34,550 0 5,281 5,281 ' <br /> siding finish, wood studs <br /> ' RJ R20 Closed Cell: Wall-Frame, Custom, Spray Foam R- 654 2,844 0 504 504 <br /> 20 <br /> R49- 166-49: Roof/Ceiling-Under Attic with Insulation on 2307 4,617 0 2,547 2,547 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R49 Blown insulation-vented ', <br /> attic, asphalt shingles ' <br /> � 21A-20-c: Floor-Basement, Concrete slab, any thickness, 3034 7,127 0 0 0 <br /> 2 or more feet below grade, no insulation below floor, , <br /> carpet covering, shortest side of floor slab is 20'wide <br /> 20P-19-c: Floor-Over open crawl space or garage, 400 1,740 0 160 160 <br /> Passive, R-19 blanket insulation, carpet covering , <br /> Subtotals for structure: 64,279 0 15,752 15,752 I <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 901 4,116 5,017 <br /> ' Lighting: 1500 5,115 5,115 <br /> Ductwork: 3,562 290 730 1,020 <br /> I Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 247, Summer CFM: 247 9,174 5,731 1,371 7,102 I <br /> Humidification(Winter)25.95 gal/day : 9,517 0 0 0 <br /> ' AED Excursion: 0 0 2,811 2,811 <br /> Total Building Load Totals: 86,531 8,123 31,274 39,397 I� <br /> [Check Fic�ures __ _ ___- - . <br /> _ _ _ _ - - - - --- --- <br /> - --� <br /> Total Building Supply CFM: 1,396 CFM Per Square ft.: 0.205 <br /> Square ft. of Room Area: 6,815 Square ft. Per Ton: 2,076 , <br /> ' Volume(ft3): 53,710 ! <br /> _ _- - -- -- -- _ ___ -- <br /> Buiiding Loads _ _ <br /> __- - -- _ - - __ -- - <br /> Total Heating Required including Ventilation Air: 86,531 Btuh 86.531 MBH <br /> Total Sensible Gain: 31,274 Btuh 79 % ' <br /> Total Latent Gain: 8,123 Btuh 21 % <br /> Total Cooling Required Including Ventilation Air: 39,397 Btuh 3.28 Tons(Based On Sensible+ Latent) <br /> _ - _____ - <br /> __ __ _ <br /> Notes <br /> - - - _ _ _ _ _ <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. I <br /> All computed results are estimates as building use and weather may vary. <br /> ' Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. I <br /> Wednesday, January 18, 2017, 6:13 PM I <br />